Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Particle Shape |
Spherical |
Particle Size |
6 µm |
Endfitting Type |
Parker-style |
Format |
Column |
Packing Solvent |
THF |
System |
HPLC |
Inner Diameter |
8 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Brand |
Shodex |
Product Type |
Columns |
Units per Package |
1 pk |
Shodex KF-801 Column, 6 µm, 8 mm x 300 mm, 1/pk
For more than five decades, Waters has been the market leader in GPC and SEC analysis. We invest in extensive research and development of chromatographic applications and methods, consistently improving techniques, and introducing new ways to old problems. We have been providing the highest quality columns and applications support for both organic- and aqueous-based size separations.
Apart from manufacturing and developing our own products, Waters also collaborates with other brands that carry the same quality of lab equipment that we assure our customers. This way you can benefit from a wide range of products, collected on a single, authentic platform, and purchase all your equipment together. In the same spirit, we are distributing the Shodex KF-801 Column, an Organic SEC (GPC) Columns for general analysis, using THF. You can be certain that the Shodex KF-801 Column meets the same high quality or performance as the GPC columns produced by Waters.
The Shodex KF-801 Column can be used across a wide range of applications where the weight of the molecular compounds varies from low to high. The column meets high performance and efficiency benchmarks while fulfilling USP L21 requirements. The product listed here is well suited to the analysis of particle size 50 Å.
You can learn more about Size Exclusion Chromatography and Gel Permeation Chromatography from the extensive literature guides on our website. From the website, you can shop for lab equipment, and find information regarding all the brands that we manufacture and collaborate with to bring you the highest quality lab equipment that meets all your chromatography needs.
You may also be interested in the Shodex KF-G Guard Column, 8 µm, 4.6 mm x 10 mm, 1/pk.The Guard column works in conjunction with the analytical column and is designed to protect it from harm while enhancing its lifetime. This is achieved by attaching the guard column to the analytical column. The guard column then removes all chemical and particulate materials from the mobile phase, protecting the column from harm, and the analysis from interference.
What Is The Recommended Pressure and pH Range For The Shodex KF-801 Column?
The recommended operating pressure for the Shodex KF-803 Column is a maximum of 6000 psi (415 Bar). The column offers an operating pH range between 2-12 pH.