Chemistry |
C8 |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Silica |
|
pH Range Min |
2 pH |
|
pH Range Max |
8 pH |
|
Temperature Limits |
45 C |
|
Maximum Pressure |
6000 psi (415 Bar) |
|
Endcapped |
Yes |
|
Silanol Activity |
Medium |
|
Particle Shape |
Spherical |
|
Particle Size |
5 µm |
|
Endfitting Type |
Waters |
|
Pore Size |
80 Å |
|
Format |
OBD Prep Column |
|
Surface Area |
220 |
|
System |
HPLC Preparative |
|
Technique |
LC/MS, LC |
|
USP Classification |
L7 |
|
Inner Diameter |
19 mm |
|
Length |
250 mm |
|
Carbon Load |
6 % |
|
UNSPSC |
41115709 |
|
Brand |
Spherisorb |
|
Product Type |
Preparative Columns |
|
Units per Package |
1 pk |
Spherisorb C8 OBD Prep Column, 80Å, 5 µm, 19 mm X 250 mm, 1/pk
Using the Spherisorb C8 OBD Prep Column, you can achieve exceptional flexibility in improving processes and lowering solvent use. A general-purpose, silica-based, reversed-phase C8 column with moderate Octyl ligand density packing and a defined carbon load of 6% is used in the lab. The preparation column is a durable and high-efficiency chromatographic equipment that can handle a wide range of applications and has been developed to be used for general purposes. These USP L7 lab equipment are used when you require a less retentive sorbent compared to the Spherisorb ODS columns.
The Spherisorb C8 OBD Prep Column will meet all of your liquid chromatography quality requirements. The lab equipment is made in the dedicated Waters chromatography chemistry manufacturing plant, which synthesizes and packs silica-based and polymeric chromatography materials into columns and solid-phase extraction devices under the strictest cGMP, ISO 9002 standards. You may rest assured that the lab equipment you receive is of the finest quality and will provide consistent and trustworthy analytical results as a consequence of your diligence. When you use the Spherisorb C8 OBD Prep Column in your lab, you get the most important performance aspects, including column efficiency, peak symmetry, column longevity, and column-to-column repeatability.
The scientists at Waters have developed the Spherisorb C8 OBD Prep Column after extensive research that was conducted to understand and address the effects of all process parameters such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume. The results of this extensive work are reflected in the column packing processes used in its manufacture to ensure that the lab equipment delivers maximum performance every time. This means that you get the best column stability and highest efficiency along with the best peak symmetry.
Waters recommends that you also invest in the Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pk.
What pH Range Works With Spherisorb C8 OBD Prep Column?
The Spherisorb C8 OBD Prep Column listed here works well between the 2-8 pH range.
What Is The Maximum Temperature Limit For The Spherisorb C8 OBD Prep Column?
The Spherisorb C8 OBD Prep Column listed here can tolerate up to 45 C temperature. It is important to note that this is applicable where the limits of pH and pressure are also observed.