Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
6.4 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
1 pk |
CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 150 mm, 1/pk
The CORTECS Shield RP18 Column is made to be versatile and produce high-efficiency results, bringing about significant advantages. The solid-core particle used in the lab equipment provides balanced retention of acids, bases, and neutrals at low and mid-range pH levels. Even at low pH levels, these characteristics lead to the delivery of outstanding peak shape for basic analytes.
Quickly resolve complicated combinations or retain resolution while improving throughput by using the all-purpose CORTECS Shield RP18 Column. Due to the solid-core particles' improved performance in lowering each of the three terms of the van Deemter equation, the column is able to produce excellent results. The B term is dropped because the solid core particles have lower particle porosity, which reduces axial diffusion, while the A term is lowered because the solid core particles pack more uniformly. Their solid core enhances heat transport, lowering radial temperature gradients, which lowers the C term.
Use the CORTECS Shield RP18 Column in analyses when you need supplementary selectivity to the C8 and C18 stationary phases. When compared to straight-chain alkyl columns, the lab equipment can be used to achieve alternate selectivity since it makes use of an embedded carbamate group in the bonded phase ligand. The CORTECS Column's solid core particle shape delivers great efficiency and lower back pressures as compared to totally porous particles of comparable particle size.
We recommend that you also explore and invest in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. TruView LCMS Certified Glass Vials use a production procedure that minimizes adsorption. High recoveries of polar analytes are produced by this technique because the circumstances limit the concentration of free ions on the glass surface. Using a number of methods, including LC/UV and UPLC/MS, all vials are extensively evaluated for dimensional features, chemical purity, and adsorption.
What Is The Maximum Pressure Recommended For The CORTECS Shield RP18 Column?
The CORTECS Shield RP18 Column listed here is able to sustain a maximum of 18000 psi (1240 Bar) pressure.
Across What pH Range Does The CORTECS Shield RP18 Column Operate?
This particular Waters CORTECS Shield RP18 Column is able to work well within the 2-8 pH range.