Chemistry |
Cyano (CN) |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Silica |
|
pH Range Min |
2 pH |
|
pH Range Max |
8 pH |
|
Temperature Limits |
45 C |
|
Maximum Pressure |
18000 psi (1240 Bar) |
|
Endcapped |
No |
|
Silanol Activity |
High |
|
Particle Shape |
Spherical |
|
Particle Size |
1.8 µm |
|
Endfitting Type |
Parker-style |
|
Pore Size |
100 Å |
|
Format |
Column |
|
Surface Area |
230 |
|
System |
UPLC, UHPLC |
|
Particle Technology |
HSS |
|
USP Classification |
L10 |
|
Inner Diameter |
3 mm |
|
Length |
100 mm |
|
Carbon Load |
5 % |
|
eCord |
Yes |
|
UNSPSC |
41115709 |
|
Brand |
ACQUITY UPLC |
|
Product Type |
Columns |
|
Units per Package |
1 pk |
ACQUITY UPLC HSS Cyano (CN) Column, 100Å, 1.8 µm, 3 mm X 100 mm, 1/pk
The ACQUITY UPLC HSS Cyano (CN) Column is an essential piece of lab equipment and well worth the investment. After a thorough investigation, the analytical column was created to provide superior chromatography performance. A high-performance general-purpose propyl cyano bonded phase is used in the column, which offers enhanced base peak shape, increased retention, and extraordinarily long column life at low pH. Columns under the ACQUITY HSS CN trademark are completely scalable and adaptable to HPLC separations.
Because the packing materials used in the lab equipment have been specifically created for use with the Waters ACQUITY UPLC System, the ACQUITY UPLC HSS Cyano (CN) Column works well with your ACQUITY UPLC system. The ACQUITY UPLC HSS Cyano (CN) Column, like all the equipment made by Waters, is created in a cGMP, ISO 9001:2000 certified facility utilizing ultra-pure reagents. In order to ensure that the lab equipment performs flawlessly and consistently, the packing material for the column goes through comprehensive testing. Chromatographic tests with acidic, basic, and neutral analytes are performed on each batch of ACQUITY HSS material, and the findings are kept to predefined tolerance limits. After each column has been independently evaluated, a Performance Chromatogram and Certificate of Batch Analysis are supplied on the eCord intelligent chip.
When compared to straight-chain alkyl columns, the ACQUITY UPLC HSS Cyano (CN) Column offers minimal hydrophobicity and exceptional selectivity. Under low- to mid-pH circumstances, the analytical column offers extremely steady retention, superb peak form, and reproducibility. This is made possible in the column by the novel monofunctional cyano bonding with guarding alkyl-side chains. Additionally, the ACQUITY UPLC HSS Cyano (CN) Column provides a special feature that works with both normal-phase and reversed-phase methods.
You may want to consider using the TruView pH Control LCMS Certified Clear Glass, 12 x 32 mm, Screw Neck Vial, with Cap and preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk to store your samples and analytes.
What Are The Temperature Limits Of The ACQUITY UPLC HSS Cyano (CN) Column?
The ACQUITY UPLC HSS Cyano (CN) Column listed here can tolerate a maximum of 45 C temperature.
What Is The Maximum Pressure That The Waters ACQUITY UPLC HSS Cyano (CN) Column Is Designed To Sustain?
This particular ACQUITY UPLC HSS Cyano (CN) Column has been designed to withstand a maximum of 18000 psi (1240 Bar) pressure.