Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
2.1 mm |
Length |
75 mm |
Carbon Load |
13 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1/pk
The ACQUITY UPLC BEH C8 columns were created using trifunctionally bonded BEH particles and to be suited for the majority of UPLC separations by giving the most pH stability. The ACQUITY UPLC BEH C8 columns, on the other hand, outperform the ACQUITY UPLC BEH C18 columns in terms of speed. The lab equipment provides faster retention of nonpolar substances while preserving chromatographic performance and enhanced peak shape delivery, making them ideal for analysis where a shorter retention period is required as the ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent.
The ACQUITY BEH packing materials were created expressly for use with the ACQUITY UPLC System and are made in a cGMP, ISO 9001 accredited facility with ultra-pure reagents. Each batch of ACQUITY BEH packing material is chromatographically tested with acidic, basic, and neutral analytes, with results held within narrow specification ranges to ensure outstanding, repeatable performance. On the eCordTM Intelligent Chip, each column is independently examined, and a Performance Chromatogram and Certificate of Batch Analysis are provided.
The trifunctional ligand bonding chemistries used in the ACQUITY UPLC BEH C8 columns ensure low pH stability and little column bleed. The specific chemistries and low pH stability of the ACQUITY UPLC BEH C8 columns, when combined with the high pH stability of the sub-2 micron particles (1.7 µm BEH particles in this case), provide the most extensive pH working range. They also use unique end-capping techniques and processes to generate outstanding peak form for bases. The best efficiencies, maximum MS sensitivities, and sharpest peak forms are achieved by particle synthesis advances and bonding chemistries. The hybrid particle substrate and reversed-phase separation mode boost this C8 column to a new standard of lower retention columns, which is very desirable for method developers in a number of applications.
Enhance the quality of your analysis using the ACQUITY UPLC BEH C8 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk. The lab equipment is designed to filter out any unwanted pollutants from the mobile stream, ensuring that the results are accurate and have no interference.
Across What pH Range Does The ACQUITY UPLC BEH C8 Column Work?
The ACQUITY UPLC BEH C8 Column listed here is able to work well across the 1-12 pH range.