Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L11 |
Inner Diameter |
1 mm |
Length |
100 mm |
Carbon Load |
14 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC CSH Phenyl-Hexyl Column, 130Å, 1.7 µm, 1 mm X 100 mm, 1/pk
The ACQUITY UPLC CSH Phenyl-Hexyl Column was developed by Waters, the foremost specialty measurement company in the world, in response to customer feedback received at multiple client forums. Using the subsequent development in particle technology, Waters created the Charged Surface Hybrid (CSH) Technology, the primary mechanism for the ACQUITY UPLC CSH columns.
Wherever you need effective lab equipment for method development that also offers alternate analyte selectivity, use the ACQUITY CSH Phenyl-Hexyl column. The trifunctionally linked C6 phenyl ligand is a strong, low-bleed sorbent that, via pi-pi interactions, selectively retains polyaromatic molecules.
The ACQUITY UPLC CSH Phenyl-Hexyl Columns stand out from Waters' other options when compared to other reversed-phase UPLC columns because they offer a larger range and a different selectivity to straight-chain-alkyl phases. The ultra-efficient ACQUITY UPLC CSH Phenyl-Hexyl Columns offer a wide range of selectivities without compromising essential performance traits like peak shape for fundamental compounds, reduced column bleed, and seamless transferability between particle sizes and column forms.
Like all of our lab equipment, the ACQUITY UPLC CSH Phenyl-Hexyl Column is made in a cGMP, ISO 9001-certified facility using ultra-pure reagents. To ensure that the anticipated great, repeatable performance is realized, the packing material for every batch of lab equipment is chromatographically tested with acidic, basic, and neutral analytes, and the results are assessed.
Deposit your samples and analytes in neutral TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The Vials use a production procedure that minimizes adsorption. High recoveries of polar analytes are produced by this technique because the circumstances limit the concentration of free ions on the glass surface. Using a number of methods, including LC/UV and UPLC/MS, all vials are extensively evaluated for dimensional features, chemical purity, and adsorption. In this test, MS detection is used in an objective manner to check for any ionized masses independent of their source.
What Is The pH Range Offered By The ACQUITY UPLC CSH Phenyl-Hexyl Column?
The Waters ACQUITY UPLC CSH Phenyl-Hexyl Column listed here is able to perform analysis within the 1-11 pH range.
Is There A Maximum Pressure Limit For The ACQUITY UPLC CSH Phenyl-Hexyl Column?
For the ACQUITY UPLC CSH Phenyl-Hexyl Column listed here, the recommended maximum pressure is 18,000 psi (1240 Bar).