Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
1 mm |
Length |
50 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC CSH C18 Column, 130Å, 1.7 µm, 1 mm X 50 mm, 1/pk
ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns. These ultra-efficient columns overcome peak shape asymmetry and poor loading capacity for basic compounds, column bleed, and rapid mobile-phase re-equilibration.
Use the ACQUITY UPLC CSH C18 Column's broad selectivity range in a variety of applications. The ACQUITY UPLC CSH C18 Column also meets a high degree of performance requirements, including superior peak shape for basic compounds, low column bleed, and high efficiency.
Because the ACQUITY UPLC CSH C18 Column was developed for the worldwide marketplace, you can develop procedures that can be easily replicated even if your laboratories are located in different regions of the world. The lab equipment provides methods that are simple to transfer and dependable. Explore more variations of the product listed here and also shop for lab equipment using our website.
Because the ACQUITY UPLC CSH C18 Column is manufactured under the strictest circumstances, you can rest assured that the lab equipment will not need to be replaced frequently and will provide consistent results.
TFA (Trifluoroacetic acid) peak shape performance is provided by the CSH technology employed in the ACQUITY UPLC CSH C18 Column without the usage of TFA. As a result, it avoids the drawbacks of TFA while providing outstanding outcomes. A more MS-friendly mobile phase, such as formic acid, results in improved peak performance. Furthermore, because formic acid does not have the lingering chromatographic effects of an ion-pairing agent, the ACQUITY UPLC CSH C18 Column allows for faster and easier method development. Under volatile, acidic, low pH mobile-phase conditions, CSH technology also gives the largest loading of basic chemicals separated. Because of the enhanced loadability, smaller preparative columns can be used, resulting in lower solvent consumption and fraction quantities.
Store your analytes and samples in the Waters TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. Part of our certified range, the vial is made using inert glass so that there is no interference in your analysis results by keeping the samples pure and contamination-free.
What pH Range Does The ACQUITY UPLC CSH C18 Column Offer?
The ACQUITY UPLC CSH C18 Column listed here offers a working pH range of 1-11 pH.
What Is The Maximum Pressure That The ACQUITY UPLC CSH C18 Column Can Tolerate?
Using the ACQUITY UPLC CSH C18 Column listed here, you can work with up to 18000 psi (1240 Bar) pressure.