Chemistry |
Amide |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L68 |
Inner Diameter |
1 mm |
Length |
150 mm |
Carbon Load |
12 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY UPLC BEH Amide Column, 1.7µm, 1.0 x 150mm, 1/pk
Increase speed, sensitivity and resolution in your UPLC analyses with the ACQUITY UPLC BEH Amide Column. This amide column offers an Ethylene-Bridged Hybrid base particle and an amide stationary phase, making this a powerful tool for carbohydrate and sugar analysis. What’s more, thanks to the rigid column structure, repeatability despite demanding conditions is ensured. Add the MaxPeak High Performance Surface technology that runs through this column and it’s easy to see why so many scientists want to add the ACQUITY UPLC BEH Amide Column to their toolkits.
Sugar and carbohydrate analysis can be difficult to achieve in LC-MS applications, as the samples are often brackish and difficult to reduce into the mobile phase stream. But if chemical or particulate fouling is the main concern you have, let us put those concerns to rest. Thanks to the strength and rigidity of the Ethylene-Bridged Hybrid (BEH) base particle, the ACQUITY UPLC BEH Amide Column is uniquely suited to handle sugar and carbohydrate samples. And if you’re transferring methods from HPLC to UPLC systems, this amide column makes it easier than ever thanks to advanced sample loadability tech.
ACQUITY UPLC Columns are characterized as offering the incredible chromatographic resolution only available with UPLC systems. But another huge benefit to owning an ACQUITY UPLC Column is that it offers best-in-class efficiency for superior separation speed and sensitivity. This especially comes in handy when working with difficult samples. And if you want to ensure your column is well protected from chemical and particulate contaminants, make sure to couple your analytical column with a VanGuard Guard Cartridge or Pre-column.
Now that you have the ACQUITY UPLC BEH Amide Column in your lab’s procurement list, have you taken a look at our incredible sample preparation products?
ACQUITY UPLC Columns make sample loading much easier, but you also want to have the right sample preparation equipment to ensure your analytical workflow runs as it should. Add the 96-well Sample Collection Plate to your cart and you’ll be ready to load samples into your UPLC column in no time.
Sample collection plates, analytical columns, column protection; this isn’t all we offer at Waters Corporation. We pride ourselves on offering the lab equipment and instruments needed by scientists across the globe. We have everything from quality control reference materials to lab informatics and various educations resources, as well. Shop lab equipment to see everything we have to offer.
What is the ACQUITY UPLC BEH Amide Column’s Maximum Pressure Threshold?
The ACQUITY UPLC BEH Amide Column can withstand pressures up to 18,000 PSI (1240 Bar).
What Is The Maximum Pressure That The ACQUITY UPLC BEH Amide Can Take?
The ACQUITY UPLC BEH Amide has been designed to withstand high pressures of up to 18000 psi (1240 Bar).