Chemistry |
Phenyl |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Hybrid |
|
pH Range Min |
1 pH |
|
pH Range Max |
12 pH |
|
Maximum Pressure |
18000 psi (1240 Bar) |
|
Endcapped |
Yes |
|
Bonding Technology |
Phenyl-Hexyl |
|
Silanol Activity |
Low |
|
Particle Shape |
Spherical |
|
Particle Size |
1.7 µm |
|
Endfitting Type |
Parker-style |
|
Pore Size |
130 Å |
|
Format |
Column |
|
Surface Area |
185 |
|
System |
UPLC, UHPLC |
|
Particle Technology |
BEH |
|
USP Classification |
L11 |
|
Inner Diameter |
3 mm |
|
Length |
150 mm |
|
Carbon Load |
15 % |
|
eCord |
Yes |
|
UNSPSC |
41115709 |
|
Brand |
ACQUITY UPLC |
|
Product Type |
Columns |
|
Units per Package |
1 pk |
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 3 mm X 150 mm, 1/pk
Count on the ACQUITY UPLC BEH Phenyl Column to reduce the possibility of technique variation due to variations brought on by variations in chromatographic medium batch or column consistency. The ACQUITY UPLC BEH Phenyl Column's trifunctionally bound phenyl-hexyl ligand enables the lab equipment to provide analytes with industry-leading chemical stability, reproducibility, and peak shape. For compounds with aromaticity brought on by pi-pi interactions, the stationary phases in the phenyl ligand offer straight-chain alkyl phases with comparable selectivity. This column's sorbent guarantees extremely low column bleed and a long column lifetime while providing you with the most phenyl sorbent that is commercially available that is chemically stable.
The ACQUITY UPLC BEH Phenyl column offers industry-leading batch-to-batch reproducibility for all analyte classes in comparison to other commercially available phenyl columns. This is due to the packing materials for the column being made under the tightest ISO 9001 standards, using ultra-pure reagents, and being built expressly for use with the ACQUITY UPLC System. To ensure that you obtain equipment that provides outstanding, repeatable performance, each batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes. The results are held to limited specification ranges. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are supplied after each column has undergone an individual test.
Learn more about the many columns and chemistries, as well as the UPLC system, under the ACQUITY brand. You can shop for lab equipment on our website and get a wealth of information on the technology behind the various pieces of equipment.
Use the ACQUITY UPLC BEH Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk in conjunction with the column in order to get the most accurate results. The lab equipment is an ideal fit for the column as it is made using the exact packing materials. This means there will be no dip in performance by using the pre-column. It works by removing any unwanted materials from the mobile phase.
What Is The Carbon Load Of The ACQUITY UPLC BEH Phenyl Column?
This particular ACQUITY UPLC BEH Phenyl Column has a carbon load of 15 %.
What Is The Maximum Pressure Offered By The ACQUITY UPLC BEH Phenyl Column?
The ACQUITY UPLC BEH Phenyl Column listed here can work with a maximum pressure of up to 18000 psi (1240 Bar).