Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Bonding Technology |
C18 SB |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Method Validation Kit |
Surface Area |
230 |
System |
UHPLC, UPLC |
Particle Technology |
HSS |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
8.5 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Column Kits |
Units per Package |
3 pk |
ACQUITY UPLC HSS C18 SB Method Validation Kit, 100Å, 1.8 µm, 2.1 mm X 100 mm, 3/pk
Gain alternative selectivity for compounds affected by silanophilic interactions by utilizing the novel non-end-capped, low-coverage silica-based C18 chemistry of the ACQUITY UPLC HSS C18 SB Method Validation Kit. The lab equipment has a specific increased silanol activity as a result of secondary interactions with leftover silanols, which increases the retention of fundamental chemicals. This happens as ionic repulsion and poor ligand density reduce non-basic analyte retention. The distinct mix of retention properties found in the ACQUITY UPLC HSS C18 SB Method Validation Kit makes it an effective method development tool for introducing changes in selectivity for Bases (SB) while generating outstanding peak shape.
Minimize the possibility of method variation brought on by irregularities in batches or columns of the chromatographic medium. Since the lab equipment was designed to provide trustworthy and repeatable results, you can count on the ACQUITY UPLC HSS C18 SB Method Validation Kit to produce consistent results year after year. For low pH separations containing complicated combinations of basic and non-basic chemicals, ACQUITY UPLC HSS C18 SB columns are employed. The ACQUITY HSS C18 SB columns can also be used for HPLC separations and are fully scalable.
The packing materials for the ACQUITY UPLC HSS C18 SB Method Validation Kit are designed specifically for use with the ACQUITY UPLC System. Additionally, they are produced in an ISO 9001- and cGMP-certified facility with ultra-pure reagents. To ensure outstanding, repeatable performance, each batch of packing material is chromatographically tested with acidic, basic, and neutral analytes. Results are held within narrow specification ranges.
Using our website, you can look for several iterations of the same item, search for all products that are compatible with the current selection, or buy lab equipment. In order to help you better understand how our equipment functions, the website also provides reference materials that go into further detail about our research and development.
Purchase the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk so that you can store your analytes in safe and inert storage.
What Is The ACQUITY UPLC HSS C18 SB Method Validation Kit’s Maximum Temperature Limit?
The ACQUITY UPLC HSS C18 SB Method Validation Kit listed here is able to tolerate a maximum of 45 C temperature.
What Is The Maximum Pressure That The ACQUITY UPLC HSS C18 SB Method Validation Kit Can Sustain?
This particular Waters ACQUITY UPLC HSS C18 SB Method Validation Kit can work with a maximum pressure of 18000 psi (1240 Bar).