Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
130 Å |
Format |
Method Validation Kit |
Surface Area |
185 |
System |
HPLC |
Particle Technology |
BEH |
USP Classification |
L7 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
13 % |
UNSPSC |
41115709 |
Brand |
XBridge |
Product Type |
Column Kits |
Units per Package |
3 pk |
XBridge BEH C8 Method Validation Kit, 130Å, 5 µm, 4.6 mm X 150 mm, 3/pk
Unmatched repeatability is provided by the XBridge BEH C8 Method Validation Kit. The column's purpose is to maintain and provide repeatability for the same product from batch to batch and year to year. This is due to Waters' opinion that reproducible column performance is one of the most crucial elements for procedure reliability. The XBridge BEH C8 Method Validation Kit is extensively tested from raw material characterization to final batch analysis to guarantee that you only receive the best lab equipment.
You can quickly create a distinctive LC/MS assay or quality control method with the XBridge BEH C8 Method Validation Kit while maximizing efficiency. The analytical column offers increased pH stability and a longer column life. In addition to this, you will gain from higher assay robustness due to better column reliability. The column is the best piece of lab equipment since it gives you the best particle efficiency and the highest peak form and capacity.
High efficiency, a symmetrical peak form, and exceptional pH stability across a broad working pH range were all taken into consideration when designing the XBridge BEH C8 Method Validation Kit. For the most demanding studies, scientists rely on the column chemistry of the XBridge BEH C8 Method Validation Kit to provide consistently trustworthy results. To help you be ready for any chromatographic problems, Waters has developed a wide variety of XBridge Columns. Using our online store, you may find out more information and shop for lab equipment.
You may also be interested in using the XBridge BEH C8 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk. The cartridge is made using the exact same packing materials that are present in the columns, making them ideally suited to conduct analysis together. The cartridge prevents any unwanted matter from entering and interfering with the analysis.
What Is The pH Limitation For The XBridge BEH C8 Method Validation Kit?
The Waters XBridge BEH C8 Method Validation Kit listed here is able to operate within the 1-12 broad pH range.
What Is The Maximum Pressure That The XBridge BEH C8 Method Validation Kit Can Withstand?
The Waters XBridge BEH C8 Method Validation Kit listed here is able to tolerate a maximum of 6,000 psi (415 Bar) pressure.