SKU: 186007780
XBridge BEH C8 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk

XBridge BEH C8 VanGuard Cartridge | 186007780


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XBridge BEH C8 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 4.6 mm I.D. XBridge BEH C8 analytical columns containing 5 µm sorbent particles.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Endfitting Type

    Waters

  • Pore Size

    130 Å

  • Format

    VanGuard Cartridge

  • Surface Area

    185

  • System

    HPLC

  • Particle Technology

    BEH

  • USP Classification

    L7

  • Inner Diameter

    3.9 mm

  • Length

    5 mm

  • Carbon Load

    13 %

  • UNSPSC

    41115709

  • Brand

    XBridge

  • Product Type

    Guards

  • Units per Package

    3 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XBridge BEH C8 VanGuard Cartridge, 130Å, 5 µm, 3.9 mm X 5 mm, 3/pk

One of the first guard column devices designed expressly for routine use, the XBridge BEH C8 VanGuard Cartridge can resist high pressures in applications run on the ACQUITY UPLC System. Along with your analytical column, it is utilized. The item on this list contains Waters-patented 130 Å pore, 5 µm BEH Technology C8 particles. To guarantee consistent performance and increased analytical column life, each batch of the XBridge BEH C8 VanGuard Cartridge undergoes quality control testing utilizing a peptide map. In this way, you can be certain that the lab equipment will function consistently for the duration of its useful life.

To protect your XBridge BEH C8 analytical column and lengthen its life, use the VanGuard Cartridge. By removing particle contamination from the mobile phase stream, the lab equipment is designed to enhance the performance of the analytical column. This particular cartridge can be used with any 3.9 mm I.D. XBridge BEH C8 analytical column with 5 µm sorbent particles.

The XBridge BEH C8 VanGuard Cartridge has been specially designed for use with Waters UPLC columns for reversed-phase liquid chromatography. Due to its distinct design, the VanGuard Cartridge is a stand-alone part that may be attached directly to the intake side of a Waters XBridge UPLC Column.

The XBridge BEH C8 VanGuard Cartridge is easy to use and convenient to install. It ensures that your XBridge BEH C8 Column is secure from damaging contaminants. By removing any chemical and particle impurities that may be present in the mobile phase stream, the lab equipment enhances and optimizes the analytical performance of the column.

We recommend that you also explore and invest in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk in order to store your samples and analytes in a chemically inert vial. Vials from Waters Certified are held to the tightest dimensional specifications in the market and are subject to HPLC cleanliness testing.

Across What pH Range Does The XBridge BEH C8 VanGuard Cartridge Operate?

This particular XBridge BEH C8 VanGuard Cartridge offers a broad pH range of 1-12.

What Is The Maximum Pressure Recommended For The XBridge BEH C8 VanGuard Cartridge?

For the XBridge BEH C8 VanGuard Cartridge listed here, the recommended maximum pressure is 18,000 psi (1240 Bar).