Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
340 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Columns |
Units per Package |
1 pk |
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk
Depend on the SunFire C18 Column for general-purpose method development at low pH. The C18 ligand of the SunFire C18 Column is highly retentive, especially for basic compounds. This makes the lab equipment well suited for purification and impurity profile assays. With the SunFire C18 Column you also get the best in particle and bonding expertise to achieve industry-level chromatographic performance.
The SunFire C18 Column offers excellent resolution, speed, and low backpressure. Additionally, it also features excellent sensitivity, high peak capacity, and ultra-low bleed to give you sharp peaks. The column can be easily used across a wide range of mass spectrometry applications. These unique attributes make the lab equipment crucial for any lab.
When compared to many traditional silica-based HPLC column brands, you can benefit from the SunFire C18 Column’s superior low pH stability that enhances column lifetime. In addition to this, by adding the analytical column to your lab, you get a dependable column that is highly efficient and offers greater sensitivity. This is achieved through the proprietary, state-of-the-art silica synthesis, bonding, end-capping, and packing technologies used in the manufacturing of the SunFire C18 Column. The sorbent of the column in combination with the new bonding and end-capping technologies deliver superior peak shape performance. You get symmetrical peaks for improved resolution and quantitation of acidic, neutral, and basic compounds at low and intermediate pH ranges.
Find an entire range of products that can be used in conjunction with this column by browsing our online store and shop for lab equipment now. For instance, you may want to explore the SunFire C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk that is designed to enhance the lifetime of your SunFire C18 Column. The Cartridge is made using the same packing material as the column and works by removing any particulate and chemical contaminants from the mobile phase.
What Is The Operating pH Range For The SunFire C18 Column?
The SunFire C18 Column can easily work within the 2-8 pH range tolerance. It is important to note, however, that the column’s lifetime will also depend on the operating temperature as well as the type and concentration of the buffer used. Elevated temperatures will decrease the column’s lifetime.