Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
340 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
SunFire |
Product Type |
Guards |
Units per Package |
3 pk |
SunFire C18 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk
Utilizing the SunFire C18 VanGuard Cartridge to filter out particle pollution from the mobile phase stream can prolong the lifespan and performance of your SunFire C18 analytical column. This lab equipment has been designed to safeguard all 3.9 mm I.D. SunFire C18 analytical columns with 3.5 µm sorbent particles.
The lab equipment is well adapted to operate with the SunFire C18 column because the SunFire C18 VanGuard Cartridge is produced using the exact packing material as the analytical column. The SunFire C18 VanGuard Cartridge increases the effectiveness and performance of the analytical column by preventing chemical contaminants and suspended particles from entering the column. The lab equipment is made to function as a piece of protective gear that is positioned between the injector and the analytical column.
Utilize the SunFire C18 VanGuard Cartridge, knowing that it complies with the strict manufacturing requirements established by Waters lab equipment. Like all of our other lab equipment, the SunFire Cartridge is made in a cGMP, ISO 9001-certified facility utilizing ultra-pure reagents. Along with this, every batch of the SunFire C18 VanGuard Cartridge packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to the highest standards to ensure that you always have lab equipment that performs superbly and reproducibly. Additionally, every pre-column is examined and approved for usage, ensuring that it will function at its peak level and improve the selectivity, sensitivity, and speed of your research.
We recommend that you store your analytes in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. Choose the vial when looking for lab equipment that vials fulfill the strictest requirements for dimensional tolerances, UV cleanliness, and MS cleanliness based on LC/GC standards. These vials are made to meet the requirements of LC/GC certification and to take into account all aspects of use, including volatility, tray design, and needle design. An HPLC test is performed on every vial to check for traces of compounds introduced during processing and manufacture.
What Are The Minimum And Maximum pH Values For The SunFire C18 VanGuard Cartridge?
The SunFire C18 VanGuard Cartridge listed here has a minimum pH value of 2 and a maximum of 8.
What Is The Maximum Pressure That The SunFire C18 VanGuard Cartridge Can Tolerate?
The recommended maximum pressure that is sustained by the SunFire C18 VanGuard Cartridge is 18,000 psi (1240 Bar).