Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
Column |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3.9 mm |
Length |
100 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Columns |
Units per Package |
1 pk |
XTerra Shield RP8 Column, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pk
Benefit from the special features of the XTerra Shield RP8 Column by including it in your collection of lab equipment. The column has several significant benefits, including mechanical strength, a highly spherical shape, purity, pore size, surface area, and the capacity to customize particle size. Utilizing conventional bonding agents enables this. Additionally, it makes the XTerra Shield RP8 Column versatile and able to retain excellent separation efficiency while providing optimal shape performance for extremely basic chemicals. Additionally, the analytical column offers increased pH stability and works with a wide pH range.
XTerra RP8 columns are general purpose, hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first-generation columns provide superior pH stability compared to a silica-based column. Utilize the XTerra Shield RP8 Column to get around the severe drawbacks of silica-based reversed-phase packing materials. The lab equipment makes use of the proprietary organic/inorganic hybrid particle technology (HPT) from Waters, which was created expressly to address the hydrolytic instability of conventional silica columns at high pH. The XTerra Shield RP8 Column is the first commercially viable substitute for silica-based column technology as a result.
High purity methyl hybrid material, which is made using a process similar to that of high-purity silica, is used in the XTerra Shield RP8 Column's construction. The XTerra packing material is created from the combined condensation of two high purity monomers as opposed to one, which is a significant distinction. Tetraethoxysilane (TEOS) and methyltriethoxysilane are used in the hybrid particle synthesis process to create the XTerra column (MTEOS). Additionally, the columns are produced in accordance with ISO 9001 guidelines, guaranteeing that every stage is carried out to the highest standards and tightest tolerances. Further, each column is evaluated independently to ensure that it performs as promised. Along with each column, certificates of batch analysis and column efficiency are also given.
Protect your analytical column from harm by using the XTerra Shield RP8 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk in conjunction with it.
What Is The pH Range Offered By The Waters XTerra Shield RP8 Column?
The XTerra Shield RP8 Column listed here offers a broad operating pH of 2-12.
What Is The Maximum Pressure That The Waters XTerra Shield RP8 Column Can Sustain?
This particular XTerra Shield RP8 Column can work with a maximum of 6000 psi (415 Bar) pressure.