Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
VanGuard Cartridge |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Guards |
Units per Package |
3 pk |
XTerra Shield RP8 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk
To extend the life of your columns while maintaining chromatographic analytical performance, connect your UPLC XTerra Shield RP8 analytical columns to the XTerra Shield RP8 VanGuard Cartridge. The cartridge maintains the separation efficiency of the columns in UPLC, UHPLC, and HPLC while removing chemical and particle contaminants. This particular cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra Shield RP8 analytical columns containing 3.5 µm sorbent particles.
It is easy to set up and use the Waters XTerra Shield RP8 VanGuard Cartridge. It shields your XTerra Shield RP8 Column against contaminants that could harm it. By filtering out any chemical and particle impurities that may be present in the mobile phase stream, the lab equipment increases and improves the analytical performance of the column.
To safeguard and extend the life of your XTerra Shield RP8 analytical column, use the XTerra Shield RP8 VanGuard Cartridge. The lab equipment increases the analytical column's performance by decreasing particle contamination in the mobile phase stream.
When used in conjunction with your analytical column, the XTerra RP8 VanGuard Cartridge is one of the first guard column devices specifically designed for routine use and can sustain high pressures in applications run on the ACQUITY UPLC System. To ensure consistent performance and enhanced analytical column life, each batch of the XTerra RP8 VanGuard Cartridge is QC tested utilizing a peptide map. This ensures that the lab equipment continues to function properly for the duration of its life.
The XTerra Shield RP8 VanGuard Cartridge was designed specifically for use with Waters UPLC columns in reversed-phase liquid chromatography. Because of its design, the VanGuard Cartridge may be quickly mounted to the intake side of a Waters XTerra UPLC Column.
You may also want to learn more about the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vial is made of inert glass and retains your samples and analytes without contaminating them, guaranteeing that you get reliable results.
Is There A pH Limitation For The XTerra Shield RP8 VanGuard Cartridge?
The XTerra Shield RP8 VanGuard Cartridge listed here is able to work across a wide pH range of 2-12 pH.