SKU: 186000414
XTerra MS C18 Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pk

XTerra MS C18 Column | 186000414


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Bonding Technology

    MS C18

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    125 Å

  • Format

    Column

  • Surface Area

    175

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    3 mm

  • Length

    50 mm

  • Carbon Load

    16 %

  • UNSPSC

    41115709

  • Brand

    XTerra

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

XTerra MS C18 Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pk

The XTerra MS C18 Column is designed for use in Mass Spectrometry (MS) applications and features crisp peak forms, high sensitivity, and big peak capacities. The XTerra MS C18 Column has one of the longest column lives over a wide pH range (1 - 12), especially when compared to traditional silica-based columns, thanks to the tri-functional bonding chemistry of the XTerra particles. These characteristics are highlighted in addition to the Column's ability to provide maximum throughput with exceptional resolution and little column bleed.

XTerra MS C18 columns are reversed-phase, hybrid-based, general-purpose C18 columns that are suitable for mass spectrometry applications. When compared to a silica-based column, these first-generation columns exhibit improved pH stability.

Waters Hybrid Particle Technology is used to create the XTerra packing materials, which comprise both inorganic (silica) and organic (organosiloxane) components, resulting in a potent combination with the benefits of each. In contrast to silica-based reversed-phase packing materials, the XTerra MS C18 column may provide you with superior separation efficiency and enhanced pH stability in your lab results, thanks to its hybrid technology.

The XTerra MS C18 column is made with ultrapure reagents to ensure that the chemical composition and purity of the hybrid particle are both controlled. The XTerra MS C18 Column, like other Waters columns, is made in state-of-the-art Waters facilities where every step of the manufacturing and packing is meticulously monitored and carried out within tight tolerances. Each column is thoroughly checked to ensure that you obtain reliable lab equipment of the highest quality. Each column is provided with Certificates of Batch Analysis and Column Efficiency to give you peace of mind about the quality control requirements.

Find various products that are compatible with XTerra MS C18 Column, including guards, vials, and elution plates on our website. The website enables you to shop for lab equipment, as well as to reach out with any queries you may have. You can direct these queries and concerns to a member of our staff, located in one of our numerous offices located globally.

You might also want to check out the XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk; this VanGuard Cartridge is designed to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.

What Are The Operating Ranges of pH And Pressure That The XTerra MS C18 Column Can Sustain?

The XTerra MS C18 Column can sustain a pH range of 1 to 12 and can perform up to a maximum pressure of 6000 psi (or 415 Bar).