Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
MS C18 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
VanGuard Cartridge |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
16 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Guards |
Units per Package |
3 pk |
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk
Connect your UPLC XTerra Shield analytical columns to the XTerra MS C18 VanGuard Cartridge to prolong the life of your columns while retaining chromatographic analytical performance. The cartridge eliminates chemical and particle impurities while preserving the separation effectiveness of the columns in UPLC, UHPLC, and HPLC. This specific cartridge is designed to safeguard all 3.9 mm and 4.6 mm I.D. 3.5 µm sorbent particle XTerra MS C18 analytical columns.
In reversed-phase liquid chromatography, the XTerra MS C18 VanGuard Cartridge was created especially for use with Waters UPLC columns. The VanGuard Cartridge's design allows for fast mounting to the intake side of a Waters XTerra UPLC Column.
The Waters XTerra VanGuard Cartridge is straightforward to install and use. It protects your XTerra Shield RP8 Column from impurities that can damage it. The lab equipment enhances and improves the analytical performance of the column by filtering out any chemical and particle contaminants that might be present in the mobile phase stream.
Use the XTerra MS C18 VanGuard Cartridge to protect and prolong the life of your XTerra analytical column. The lab equipment improves the performance of the analytical column by reducing particle contamination in the mobile phase stream.
The XTerra MS C18 VanGuard Cartridge is one of the first guard column devices specifically created for everyday usage and can withstand high pressures in applications run on the ACQUITY UPLC System when used in conjunction with your analytical column. Each batch of the XTerra MS C18 VanGuard Cartridge is QC verified using a peptide map to guarantee consistent performance and prolonged analytical column life. This guarantees that the lab equipment will continue to operate correctly over its entire life.
You may also want to explore in detail the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. These vials are made to meet the requirements of LC/GC certification and to take into account all aspects of use, including volatility, tray design, and needle design. An HPLC test is performed on every vial to check for traces of compounds introduced during processing and manufacture.
Across What pH Range Does The XTerra MS C18 VanGuard Cartridge Operate?
The XTerra MS C18 VanGuard Cartridge listed here is able to work well within the 1-12 pH range.
What Is The Maximum Pressure That The XTerra MS C18 VanGuard Cartridge Can Tolerate?
This particular XTerra MS C18 VanGuard Cartridge is able to tolerate a maximum of 18000 psi (1240 Bar) pressure.