Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
90 Å |
Format |
Column |
Surface Area |
100 |
System |
UHPLC, UPLC |
Particle Technology |
Solid Core |
USP Classification |
L11 |
Inner Diameter |
4.6 mm |
Length |
100 mm |
Carbon Load |
5.9 % |
UNSPSC |
41115709 |
Brand |
CORTECS |
Product Type |
Columns |
Units per Package |
3 pk |
CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 3/pk
Choose the Waters CORTECS Phenyl Column to achieve excellent efficiency and lower operating back pressure when compared to completely porous particles of comparable particle size. This enables you to carry out techniques using conventional LC instruments while preserving effectiveness and resolution. Longer columns can be used to enhance resolution for co-eluting peaks in complex sample combinations.
Use the CORTECS Phenyl Column's alternate selectivity to C8 and C18 stationary phases to take advantage of analyte interactions with the benzyl ring. When utilizing methanol as the organic modifier, the variations in selectivity for this phase are especially noticeable for aromatic molecules. In addition to this, the lab equipment can easily deliver exceptionally minimal column MS bleed, a long lifetime, and good peak form.
The CORTECS Phenyl Column packing materials are manufactured in a cGMP, ISO 9001 accredited facility using ultra-pure reagents and were developed specifically for use with the ACQUITY UPLC System. In order to guarantee exceptional, consistent performance, each batch of the CORTECS Phenyl Column packing material is chromatographically tested with acidic, basic, and neutral analytes. Each column is separately analyzed, and the results are given on the eCord Intelligent Chip in the form of a Performance Chromatogram and Certificate of Batch Analysis. The bonded phase batch number and the findings of the analytical tests are both listed on the Certificate of Analysis. The Performance Chromatogram, on the other hand, offers the batch number, column serial number, USP plate count, USP tailing factor, USP retention factor, and the chromatographic test conditions in addition to summarizing the performance of each particular column. It is recommended that these data sets be documented and kept for later use.
You may also want to invest in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vials that are TruView LCMS Certified are made using strictly regulated manufacturing and handling techniques. Mass spectrometers are used to check for cleanliness, and ACQUITY/MS/MS is used to check for low analyte adsorption.
What Is The Carbon Load Of The CORTECS Phenyl Column?
The Waters CORTECS Phenyl Column listed here has a carbon load of 5.9 %.
What Maximum Pressure Can The CORTECS Phenyl Column Tolerate?
This particular CORTECS Phenyl Column has been designed to withstand a maximum of 18000 psi (1240 Bar) pressure.