Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
CSH |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
100 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
XSelect |
Product Type |
Columns |
Units per Package |
3 pk |
XSelect CSH C18 Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pk
With the XSelect CSH C18 Column, you can perform higher resolution separations, which are necessary for isolating and quantifying complicated samples. The XSelect CSH C18 Column achieves this through the analytical column's unique phases, which combine efficiency and selectivity to improve the resolution of exceedingly complex samples. The lab equipment will save you time and effort while constructing a chromatographic test because it is fully compatible with all HPLC, UPLC, and UHPLC technologies. Furthermore, because of its outstanding batch-to-batch consistency, the analytical column allows you to swiftly create robust procedures.
Use the XSelect CSH C18 Column to deliver unmatched selectivity and reproducibility for your chromatographic analysis. The lab equipment is designed to offer diverse analyte selectivity to separate closely eluting sample constituents. The column can be used as a general-purpose column that provides alternative selectivity compared to other C18 sorbents available for commercial use. The Charged Surface Hybrid (CSH) technology embedded in the column will help you overcome column-related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
When comparing the XSelect CSH C18 Column to core-shell columns, outstanding performance and equal back pressure are also major advantages. Due to the use of Charged Surface Hybrid (CSH) technology in the analytical column, the XSelect CSH C18 Column, like other completely porous particle columns, has better loading capacity and particle size scalability. The next generation of particle technology, CSH Technology, greatly enhances all aspects of liquid chromatography performance in acidic, low ionic strength mobile phases. The column also allows for the most flexibility in the technique development, especially when using low pH mobile phases. This is because the XSelect CSH C18 Column's non-end-capped sorbent enhances acidic chemical retention.
Opt to shop for lab equipment from our online store to get the best prices in the market.
We recommend that you store your analytes in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What pH Range Does The XSelect CSH C18 Column Offer?
The XSelect CSH C18 Column listed here offers a broad operating pH range of 1-11.
What Maximum Pressure Can The XSelect CSH C18 Column Sustain?
The XSelect CSH C18 Column listed here can easily tolerate up to 18000 psi (1240 Bar) pressure.