Chemistry |
Phenyl |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Phenyl-Hexyl |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UPLC, UHPLC |
Particle Technology |
BEH |
USP Classification |
L11 |
Inner Diameter |
2.1 mm |
Length |
30 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk
Like the Waters XBridge BEH Phenyl Column, the ACQUITY BEH Phenyl line of columns also provides complementary selectivity to C18 stationary phases, especially for polyaromatic compounds, and also provides you with the most chemically stable phenyl sorbent on the market. You get ultra-low column bleed, long column lifetimes, and excellent peak shape by adding the ACQUITY UPLC BEH Phenyl Column to your lab equipment.
The Waters ACQUITY UPLC BEH Phenyl Column listed here is ideally suited for the analysis of analytes with pore size 130Å and particle size 1.7 µm. Using the listed 2.1 mm I.D. column, you can utilize a wide pH stability range (1-12). To improve your purchase experience, the column is packaged as a bulk pack, so you get 3 columns in one purchase.
To minimize the risk of method variation due to differences caused by chromatographic media batch or column inconsistency, utilize the ACQUITY UPLC BEH Phenyl Column. With its trifunctionally-bonded phenyl-hexyl ligand, you can benefit from industry-leading chemical stability, reproducibility, and peak shape for all analytes. Incorporated in the phenyl ligand are stationary phases that provide complementary selectivity to straight-chain alkyl phases, particularly for molecules containing aromaticity due to pi-pi interactions.
The ACQUITY UPLC BEH Phenyl column delivers outstanding batch-to-batch reproducibility for all analyte types, especially when compared to other commercially available phenyl columns. This is the result of carefully researched packing materials that have been designed specifically for use with the ACQUITY UPLC System. These materials are manufactured with the strictest ISO 9001 conditions and stringent process control. Further, each batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes, and the results are held to narrow specification ranges to make sure you receive equipment that gives excellent reproducible performance. A Performance Chromatogram and Certificate of Batch Analysis are provided on the eCord™ Intelligent Chip with each column after it has been individually tested.
We recommend that you shop for lab equipment directly from us to get original Waters equipment. You may also want to learn more about the ACQUITY UPLC BEH Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk.
What Is The Use Of Polyaromatic Hydrocarbons?
Polyaromatic Hydrocarbons (PAHs) are used as intermediaries in pharmaceuticals, agricultural products, photographic products, thermosetting plastics, lubricating materials, and other chemical industries. Their general uses include the manufacture of pigments, dyes, plastics, pesticides, and pharmaceuticals.