Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
9 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
USP Classification |
L3 |
Inner Diameter |
1 mm |
Length |
100 mm |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
3 pk |
ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk
To influence the retention, selectivity, and sensitivity of ionizable chemicals, rely on the ACQUITY UPLC BEH HILIC Column. The ACQUITY UPLC BEH HILIC Column's packing materials offer remarkable performance because they were created especially for use with the ACQUITY UPLC System.
The Hydrophilic-Interaction Chromatography (HILIC), an alternative chromatographic method that can be used to successfully improve the retention of extremely polar species, is utilized by the ACQUITY UPLC BEH HILIC Column. Additionally, it gives mixtures of polar and ionizable chemicals an orthogonal separation mode. This is accomplished by eluting analytes in the sequence of increasing hydrophilicity utilizing a polar stationary phase in combination with an acetonitrile-rich, low-aqueous mobile phase.
Under HPLC HILIC settings, the special ACQUITY UPLC BEH HILIC Column has been tested and refined to achieve effective, repeatable separations. Unbonded BEH substrates are present in the lab equipment, which was built to hold and sort extremely polar chemicals. Long column lives are a result of the chemical stability of the BEH particle and the silica-based HILIC phases.
To attain previously unprecedented levels of effectiveness, peak symmetry, and chemical stability, use the ACQUITY UPLC BEH HILIC Column. For particularly polar analytes, the analytical column allows the delivery of both extremely low and high-pH stability. The customer has the ability to utilize a broad mobile phase pH range while using the ACQUITY UPLC BEH HILIC Column.
The ACQUITY UPLC BEH HILIC Column, like all of our lab equipment, is produced in a cGMP, ISO 9001-certified facility using ultra-pure reagents. Additionally, each batch of the ACQUITY UPLC BEH HILIC Column packing material is tested chromatographically with acidic, basic, and neutral analytes, and the results are held to strict scrutiny to ensure that the equipment will perform as intended—excellently and reproducibly—so that your lab receives only high-quality equipment.
Browse through our website to find the full selection of our analytical columns and their guards. The website will also point you in the direction of complementary items that can be utilized with the columns to round out your analytical capabilities and shop for lab equipment.
You may also be interested in storing your analytes in the TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
What Is The pH Range For The ACQUITY UPLC BEH HILIC Column?
For this particular column, the pH range is 1-9.
What Is The Maximum Pressure Recommended For The ACQUITY UPLC BEH HILIC Column?
This ACQUITY UPLC BEH HILIC Column is able to withstand up to 18,000 psi (1240 Bar) pressure.