This is an Application Brief and does not contain a detailed Experimental section.
This application brief demonstrates analysis of camphorsulfonic acid in rat plasma on Oasis Wax.
Camphorsulfonic acid is a strong acid with a pKa of approximately 1.5. The best SPE recoveries for this type of acid are on Oasis WAX products.
| 
                     Oasis WAX 10 mg 96-Well Plate  | 
            |
|---|---|
| 
                     Condition:  | 
                     500 μL MeOH  | 
            
| 
                     Equilibrate:  | 
                     500 μL H2O  | 
            
| 
                     Load:  | 
                     500 μL (250 μL rat plasma, diluted 1:1 with 4% H3PO4)  | 
            
| 
                     Wash 1:  | 
                     500 μL 2% FA, pH 2.7  | 
            
| 
                     Wash 2:  | 
                     500 μL MeOH  | 
            
| 
                     Elute:  | 
                     250 μL (125 μL x 2) 5% NH4OH in MeOH  | 
            
| 
                     Options:  | 
                     1. Dilute 250 μL H2O with 2% FA 2. Evaporate/ Reconstitute 3. Direct inject  | 
            
| 
                     Inject:  | 
                     10 μL  | 
            
| 
                     Condition:  | 
                     200 μL MeOH  | 
            
| 
                     Equilibrate:  | 
                     200 μL H2O  | 
            
| 
                     Load:  | 
                     100 μL (50 μL rat plasma diluted 1:1 with 4% H3PO4)  | 
            
| 
                     Wash 1:  | 
                     200 μL 2% FA, pH 2.7  | 
            
| 
                     Wash 2:  | 
                     200 μL MeOH  | 
            
| 
                     Elute:  | 
                     50 μL (25 μL x 2) 5% NH4OH in MeOH  | 
            
| 
                     Options:  | 
                     1. Direct injection 2. Dilute with 50 μL H2O with 2% FA 3. Evaporate/ Reconstitute  | 
            
| 
                     Inject:  | 
                     10 μL  | 
            
| 
                     Column:  | 
                     SunFire C18 2.1 x 20 mm IS, 3.5 μm  | 
            
| 
                     Mobile phase A:  | 
                     10 mM CH3COO-NH4+, pH 5.5  | 
            
| 
                     Mobile phase B:  | 
                     MeOH with 10 mM CH3COO-NH4+, pH 5.5  | 
            
| 
                     Flow rate:  | 
                     0.4 mL /min  | 
            
| 
                     Injection volume:  | 
                     10 μL  | 
            
| 
                     Column temp:  | 
                     Ambient  | 
            
| 
                     Instrument:  | 
                     2777 Sample Manager, 1525μ Binary HPLC Pump and Quattro Premier  | 
            
| 
                     ESI- source temp:  | 
                     150 °C  | 
            
| 
                     Desolvation temp:  | 
                     350 °C  | 
            
| 
                     Cone gas flow:  | 
                     50 L /Hr  | 
            
| 
                     Desolvation gas flow:  | 
                     600 L /Hr  | 
            
| 
                     Collision cell:  | 
                     2.2e-3 bar (Ar gas)  | 
            
WA60084, June 2007