Engineered to tackle the toughest challenges, MaxPeak Premier OBD    Preparative Columns bring unmatched efficiency, scalability, and purity    to your lab. Transform your process with a simple column change—and watch your results soar.

제품 번호: 186011825
XBridge Premier Oligonucleotide BEH C18,130Å, OBD Prep Column, 5µm, 19 mm x 150 mm, 1/pk


맞춤화 견적으로 간소화된 구매 프로세스

맞춤화 견적으로 간소화된 구매 프로세스

Waters.com에서 제품을 둘러보고 원하는 품목을 장바구니에 추가하기

장바구니로 이동하기

견적 요청을 선택하여 즉시 견적 받기


제품 설명

XBridge Premier Oligonucleotide BEH C18, 130Å, 5µm, 19 mm x 150 mm, OBD preparative columns use MaxPeak High Performance Surface hardware technology which significantly reduces unwanted analyte/surface interactions that can lead to poor peak shape and losses in signal intensity. These columns prevent undesired analyte/surface interactions through the power of MaxPeak HPS Technology, which is designed to increase analyte recovery, sensitivity, peak shape and reproducibility by minimizing analyte/surface interactions that can lead to sample losses. XBridge Premier BEH C18 column can be employed across an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand allows for general use and is a suitable universal column for scouting and predictable prep scale-up. These columns offer the broadest usable pH range, superior low pH stability, and ultra-low column bleed. XBridge Premier OBD preparative columns enable exceptional separation performance, robustness and throughput for purification workflows while enabling seamless UPLC to Prep scaling. XBridge Premier OBD preparative columns enable exceptional separation performance, robustness and throughput for purification workflows while enabling seamless UPLC to Prep scaling. These XBridge BEH C18 reversed-phase columns are packed with the same quality control (QC) tested sorbent (each batch is tested with peptide standards to ensure lot-to-lot performance and reproducibility).

사양

  • 케미스트리

    C18

  • 분리 모드

    역상

  • 입자 기질

    Silica

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Temperature Limits

    80 C (Low pH)/60 C (High pH)

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

  • 본딩 기술

    BEH

  • Particle Shape

    Spherical

  • 입자 크기

    5 µm

  • Endfitting Type

    Waters

  • 공극 크기

    130 Å

  • 형식

    Premier 컬럼, OBD Prep 컬럼

  • Packing Solvent

    100% Acetonitrile

  • 표면적

    185

  • 시스템

    HPLC Preparative

  • 입자 기술

    CSH

  • Technique

    LC, LC/MS

  • USP 분류

    L1

  • 내경

    19 mm

  • 길이

    150 mm

  • Carbon Load

    18 %

  • UNSPSC

    41115709

  • 응용

    올리고뉴클레오타이드

  • 브랜드

    XBridge

  • 제품 유형

    분취용 컬럼

  • Units per Package

    1 pk

  • eConnect

    No

제품 지원

문서

문서



어떤 작업을 하시겠습니까?

어떤 작업을 하시겠습니까?
도움이 필요하십니까?

관련 제품

맨 위로 돌아가기 맨 위로 돌아가기