제품 번호: 186008808
nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 150 mm, 1/pk

nanoEase M/Z 펩티드 CSH C18 칼럼 | 75 µm X 150 mm | 186008808


맞춤화 견적으로 간소화된 구매 프로세스

맞춤화 견적으로 간소화된 구매 프로세스

Waters.com에서 제품을 둘러보고 원하는 품목을 장바구니에 추가하기

장바구니로 이동하기

견적 요청을 선택하여 즉시 견적 받기


제품 설명

nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 150 mm columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. All M/Z columns withstand 15kpsi (1,000 Bar)operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. These columns are equipped with the ZenFit connector, an easy to use, fingertight, tool free liquid connection. This ensures reproducible, leak free connections. The fittings will fit into Waters V-Detail ports as well as into Rheodyne/Vici compatible valves." This specific offering contains Waters patented CSH Technology 130Å pore, C18, 1.7 µm particles. The first choice for peptide separations, CSH particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. They exhibit little dependence on strong ion pairing agents, making them ideal for LC or LC-MS applications. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) to before being QC accepted as a Peptide separation column.

Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute

사양

  • 케미스트리

    C18

  • 분리 모드

    역상

  • 입자 기질

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    10 pH

  • Maximum Pressure

    15000 psi (1034 Bar)

  • Endcapped

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • 입자 크기

    1.7 µm

  • Endfitting Type

    10-32 for 1/16" male /360um open

  • 공극 크기

    130 Å

  • QC Tested

    Peptide

  • 형식

    컬럼

  • 표면적

    185

  • 시스템

    Nano/Micro

  • 입자 기술

    CSH

  • USP 분류

    L1

  • 내경

    75 µm

  • 길이

    150 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115711

  • 응용

    펩타이드

  • 브랜드

    nanoEase M/Z

  • 제품 유형

    컬럼

  • Units per Package

    1 pk