제품 번호: 176005290
GlycoWorks Rapi-Fluor-MS N-Glycan Eco Starter Kit with Premier UPLC Glycan BEH Column - 24 samples


맞춤화 견적으로 간소화된 구매 프로세스

맞춤화 견적으로 간소화된 구매 프로세스

Waters.com에서 제품을 둘러보고 원하는 품목을 장바구니에 추가하기

장바구니로 이동하기

견적 요청을 선택하여 즉시 견적 받기


제품 설명

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in as little as 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Eco Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS's (RFMS) unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive. This starter kit includes the GlycoWorks Deglycosylation Module, GlycoWorks Eco Labeling Module, GlycoWorks Eco Clean-up Module, GlycoWorks Sample Collection Module, as well as the ACQUITY Premier UPLC Glycan BEH Amide Column, 1.7 µm, 2.1 x 150 Column and Mobile-Phase Concentrate: Ammonium Formate. It contains materials to process 24 samples in a 3x8 format. The kit contains: GlycoWorks Deglycosylation Module: (1) 0.035 ml/vial Rapid PNGaseF Enzyme, (1) 0.25 ml/vial Glycoworks Rapid Buffer, (1) 3 vials of 3 mg/vial RapiGest SF Surfactant, (1) Intact mAb Mass Check Standard *Shipped in a separate box; GlycoWorks RapiFluor-MS Eco Labeling Module: (3) 9 mg/vial RapiFluor-MS Reagent, (3) 1 mL/vial Reagent Solvent (Anhydrous DMSO); GlycoWorks RFMS Eco Clean-up Module: (4) 5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7), (1) GlycoWorks HILIC µElution Plate; GlycoWorks Sample Collection Module: (15) 1 mL tubes for deglycosylation and labeling reaction, (15) 600 µL tube inserts for SPE eluate collection, (15) Cap strips with slits for direct injection, (1) 1 mL round collection tray, (1) Waste tray; Extras: (1) 50 mM Ammonium Formate Solution—Glycan Analysis (186007081), (1) ACQUITY Premier UPLC Glycan BEH Amide Column, 130Å, 1.7μm, 2.1 x 150 mm (186009549), (1) RapiFluor-MS Glycan Performance Test Standard
Suggested Use: Eco-Friendly, Released N-linked Glycan Analysis

사양

  • Number of Analysis

    96

  • Type

    Sample Preparation Workflow

  • Packages per kit

    1

  • Separation Mode

    UPLC/UHPLC/HPLC

  • Detection Method

    HRMS, MS, MS/MS, UV

  • Storage Condition

    Refer to the storage recommendations of each sub-package

  • 시스템 유형

    LC-MS

  • Shelf Life

    Refer to the storage recommendations of each sub-package

  • UNSPSC

    41116104

  • 응용

    글라이칸

  • 브랜드

    GlycoWorks

  • 제품 유형

    응용 키트

제품 지원

문서

문서



어떤 작업을 원하십니까?

어떤 작업을 원하십니까?
도움이 필요하십니까?
맨 위로 돌아가기 맨 위로 돌아가기