SKU: 176005290
GlycoWorks Rapi-Fluor-MS N-Glycan Eco Starter Kit with Premier UPLC Glycan BEH Column - 24 samples


カスタム見積で購入プロセスを合理化

カスタム見積で購入プロセスを合理化

Waters.com でショッピングし、カートにアイテムを追加します

ショッピングカートに移動します

[見積依頼]を選択して、見積もりを入手します


製品名

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in as little as 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Eco Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS's (RFMS) unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive. This starter kit includes the GlycoWorks Deglycosylation Module, GlycoWorks Eco Labeling Module, GlycoWorks Eco Clean-up Module, GlycoWorks Sample Collection Module, as well as the ACQUITY Premier UPLC Glycan BEH Amide Column, 1.7 µm, 2.1 x 150 Column and Mobile-Phase Concentrate: Ammonium Formate. It contains materials to process 24 samples in a 3x8 format. The kit contains: GlycoWorks Deglycosylation Module: (1) 0.035 ml/vial Rapid PNGaseF Enzyme, (1) 0.25 ml/vial Glycoworks Rapid Buffer, (1) 3 vials of 3 mg/vial RapiGest SF Surfactant, (1) Intact mAb Mass Check Standard *Shipped in a separate box; GlycoWorks RapiFluor-MS Eco Labeling Module: (3) 9 mg/vial RapiFluor-MS Reagent, (3) 1 mL/vial Reagent Solvent (Anhydrous DMSO); GlycoWorks RFMS Eco Clean-up Module: (4) 5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7), (1) GlycoWorks HILIC µElution Plate; GlycoWorks Sample Collection Module: (15) 1 mL tubes for deglycosylation and labeling reaction, (15) 600 µL tube inserts for SPE eluate collection, (15) Cap strips with slits for direct injection, (1) 1 mL round collection tray, (1) Waste tray; Extras: (1) 50 mM Ammonium Formate Solution—Glycan Analysis (186007081), (1) ACQUITY Premier UPLC Glycan BEH Amide Column, 130Å, 1.7μm, 2.1 x 150 mm (186009549), (1) RapiFluor-MS Glycan Performance Test Standard
Suggested Use: Eco-Friendly, Released N-linked Glycan Analysis

仕様

  • Number of Analysis

    96

  • Type

    Sample Preparation Workflow

  • Packages per kit

    1

  • Separation Mode

    UPLC/UHPLC/HPLC

  • Detection Method

    HRMS, MS, MS/MS, UV

  • Storage Condition

    Refer to the storage recommendations of each sub-package

  • システムの種類

    LC-MS

  • Shelf Life

    Refer to the storage recommendations of each sub-package

  • UNSPSC

    41116104

  • アプリケーション

    糖鎖

  • ブランド

    GlycoWorks

  • 製品の種類

    アプリケーションキット

製品サポート

ドキュメント

ドキュメント



お探しの情報は何ですか?

お探しの情報は何ですか?
支援をご希望ですか?
トップに戻る トップに戻る