SKU: 186008807
nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 100 mm, 1/pk

nanoEase M/Z Proteine BEH C4 Colonna, 300Å, 1.7 µm, 100 µm X 100 mm, 1/pk | 186008805


Semplifica gli acquisti con preventivi personalizzati

Semplifica gli acquisti con preventivi personalizzati

Acquista su Waters.com e aggiungi articoli al carrello

Seleziona Richiedi un Preventivo per ottenere immediatamente il preventivo


Descrizione del Prodotto

nanoEase M/Z Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 100 mm columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. All M/Z columns withstand 15kpsi (1,000 Bar)operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. These columns are equipped with the ZenFit connector, an easy to use, fingertight, tool free liquid connection. This ensures reproducible, leak free connections. The fittings will fit into Waters V-Detail ports as well as into Rheodyne/Vici compatible valves." This specific offering contains Waters patented CSH Technology 130Å pore, C18, 1.7 µm particles. The first choice for peptide separations, CSH particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. They exhibit little dependence on strong ion pairing agents, making them ideal for LC or LC-MS applications. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c (p/n: 186006371) to before being QC accepted as a Peptide separation column.

Suggested Uses: Bottom-up Proteomics, Nano-flow, Trap and Elute

Specifiche

  • Chimica

    C18

  • Modalità di separazione

    Fase inversa

  • Substrato particellare

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    10 pH

  • Maximum Pressure

    15000 psi (1034 Bar)

  • Endcapped

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Diametro delle particelle

    1.7 µm

  • Endfitting Type

    10-32 for 1/16" male /360um open

  • Dimensioni dei pori

    130 Å

  • QC Tested

    Peptide

  • Formato

    Colonna

  • Superficie

    185

  • Sistema

    Nano/Micro

  • Tecnologia delle particelle

    CSH

  • Classificazione USP

    L1

  • Diametro interno

    75 µm

  • Lunghezza

    100 mm

  • Carbon Load

    15 %

  • UNSPSC

    41115711

  • Applicazione

    Peptidi

  • Marchio

    nanoEase M/Z

  • Tipo di prodotto

    Colonne

  • Units per Package

    1 pk