Information. Informatics. Impact. SYNAPT enables extensive characterization of complex mixtures and molecules with uncompromising qualitative and quantitative performance, streamlined workflows and unparalleled platform versatility.
Ultimate performance for UPLC/MS/MSCombine StepWave and UPLC separations with Quantitative Time-of-Flight (QuanTof) technologies, for the highest peak capacity and data quality. StepWave is the most sensitive and robust ion source available through its unique ability to 'actively' select ions and 'passively' reject neutral contaminants. Unlike all other mass analyzers, QuanTof provides; high mass resolution, accurate mass and isotope ratios, wide (in-spectrum and quantitative) dynamic range and m/z range - all together at the fastest acquisition rates, even for samples with high matrix burden. |
Powerful data independent & data dependent solutionsFor profiling complex mixtures with unparalleled coverage and efficiency. The generic UPLC/MSE acquisition technique records fragment ion data for every detectable molecular ion with superior duty cycle to other 'data independent analysis' (DIA) techniques, while our Informatics technologies streamline data analysis for the widest range of applications. For more efficient and effective targeted MS/MS, leverage our latest 'data dependent' workflows. Drive to even lower limits of quantification using high resolution MRM workflow, and enhance compound coverage in discovery experiments with greater MS/MS sensitivity using FastDDA. |
|
CID and ETD Fragmentation CapabilitiesThe dual collision cell arrangement of TriWave enhances MS/MS possibilities, by providing Collision Induced Dissociation (CID) and/or Electron Transfer Dissociation (ETD) fragmentation with high resolution and accurate mass measurements. Our affordable ETD option is engineered for the highest performance (fragmentation efficiency) and flexibility with ease-of-use and ease-of-maintenance. The resolving quadrupole is available in 4KDa, 8KDa or 32KDa mass range options for MS/MS of small to macromolecular species. |
Waters’ ion source architecture interfaces with a huge range of techniques, from separation with UPLC, nanoUPLC, HDX Automation, APGC and UPC2 to ionisation with ESI, APCI, ASAP, DESI, DART and LDTD. They are quickly interchangeable and ready to use within minutes. For direct analysis methods, upgrade to HDMS capability and T-Wave IMS technology which provides the highest post-ionisation selectivity and specificity. This is particularly advantageous when combined with the high performance MALDI option, which can be rapidly switched with atmospheric pressure ion sources.
|
Upgrade to three dimensions of resolution!Retention. Mobility. Mass. Sometimes chromatography and mass resolution are not enough. The simple, quick and unique upgrade path to SYNAPT High Definition MS capability and high-efficiency T-Wave ion mobility technology, gives you access to an additional dimension of separation, based on molecular size and shape. The unique ability to exploit the collision cross section property of a molecule delivers the highest levels of selectivity, specificity, sensitivity and structural insight. The huge range of benefits feature isomer separation, elimination of interferences, generation of cleaner spectra and even the ability to better confirm compound ID. |
See real-world benefit of HDMS
DMPK and Bioanalysis Knowledge Center
Learn more about Targeted High Resolution Quantification with Tof-MRM and HD-MRM