SKU: 700009875
Tubing Assembly, Capillary, 40 µm x 10 in, V-V, HP

Tubing Assembly | Capillary | 40 µm x 10 in | V-V | HP | 700009875


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

This spare part is a Waters Quality part

Specifications

  • UNSPSC

    41115720

  • Brand

    Waters Quality Parts

  • Product Type

    Spare Parts Kits

  • Units per Package

    1 pk

  • Replacement Schedule

    As Required

Product Support

Documents

Documents

What do you want to do?

What do you want to do?
Back To Top Back To Top

BPA Method Kit

To take advantage of the Waters-developed solution for the analysis of Bisphenol A levels in drinking water, you need the proper tools and resources. And luckily for you, we’ve developed a product that includes them all with the BPA Method Kit. Fully compliant with ASTM Method D7574-09 and optimized for use with ACQUITY UPLC systems, the BPA Method Kit comes with everything you need to perform Bisphenol A analysis and develop conclusions from that data. What’s more, this kit has been strictly tested for quality control purposes and for its specific application. That way you can be completely sure of the performance and implementation of this workflow solution right out of the box. Purchase the BPA Method Kit now and take advantage of a streamlined Bisphenol A analysis solution tomorrow.

What’s in the BPA Method Kit?
The BPA Method Kit comes with an ACQUITY BEH C18 Column, an ACQUITY Isolator Column, Oasis HLB 5cc LP Glass Cartridges and LC-MS Certified Vials. This kit utilizes solid-phase extraction to extract the Bisphenol A contained in drinking water, separating it using liquid chromatography, then identifying it using a mass spectrometer. Through the ASTM Method D7574-09 and the ACQUITY Bisphenol A analysis workflow solution, you can achieve simple, easy and repeatable Bisphenol A detection in drinking water.

If you’re just developing separations to isolate Bisphenol A in a sample, then you may want the BPA Column Kit. This kit just comes with the ACQUITY BEH C18 Column and ACQUITY Isolator Column needed to properly perform the separation of sample and the isolation of Bisphenol A from that sample. These columns were chosen because of their unique selectivity and performance properties when being used in the ASTM Method D7574-09.

To take full advantage of the BPA Method Kit, you need to ensure you have your ACQUITY system properly calibrated and verified for performance. Did you know that we offer the quality control reference materials for system performance verification?
We do, plus many other products and resources needed to achieve success in a lab environment. Simply shop lab equipment to discover everything we have to offer.

What System Does the Capillary Tubing Assembly (PN# 700009875) Belong To?

The Capillary Tubing Assembly (PN# 700009875) belongs to the ACQUITY M-Class UPLC System.