Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
335 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Columns |
Units per Package |
1 pk |
Symmetry C8 Column, 100Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk
Utilize the Symmetry C8 Column, a piece of lab equipment that provides exceptional reproducibility, to do away with the requirement for revalidating procedures with each new batch of columns. The Symmetry C8 Column has one of the strictest column specifications in the business and is made up of monofunctional bonded C8 ligands on a high-purity base-deactivated silica.
The Symmetry C8 Column gives not only high repeatability year after year but also long life to already established analytical techniques. The Symmetry C8 Column is the ideal lab piece of equipment for all your chromatographic needs because it lasts over 10,000 injections with almost no efficiency loss, barely any increase in backpressure, and barely any change in retention time.
The Symmetry C8 Column makes use of the two crucial variables that affect column longevity. They are the mechanical stability of the packed bed and the hydraulic stability of the packing material. You can give dependable performance by utilizing the synergy of these crucial Symmetry C8 Column characteristics.
The Symmetry C8 packing materials are produced in a cGMP, ISO 9001-certified facility using ultra-pure reagents and were created expressly for use with the ACQUITY UPLC System. To ensure repeatable performance, each batch of Symmetry C8 packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to limited specification ranges. On the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are supplied after each column has undergone an individual test.
Invest in the Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk in order to protect your analytical column from the intrusion of unwanted chemical and particulate pollutants that interfere with the chromatographic analysis. The cartridge is manufactured using the exact packing materials that are present in the column, making the column and cartridge an ideal fit for one another. It also ensures that the column lasts a long time, reducing the need to repeatedly replace the lab equipment.
What Is The Carbon Load Of The Symmetry C8 Column?
The Waters Symmetry C8 Column listed here carries a carbon load of 12 %.
What Is The Maximum Recommended Pressure For The Symmetry C8 Column?
The Waters Symmetry C8 Column listed here has been designed to withstand a maximum of 6,000 psi (415 Bar).