Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
1500 psi (100 Bar) |
Endcapped |
Yes |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Pore Size |
60 Å |
Format |
Radial-Pak Column |
Surface Area |
120 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
8 mm |
Length |
100 mm |
Carbon Load |
7 % |
UNSPSC |
41115709 |
Brand |
Nova-Pak |
Product Type |
Columns |
Units per Package |
1 pk |
Nova-Pak C18 Radial-Pak Column, 60Å, 4 µm, 8 mm X 100 mm, 1/pk
Use the Nova-Pak C18 Radial-Pak Column in your lab to get higher resolution and faster, more efficient chromatography. The lab equipment’s shorter length makes it possible to use less solvent consumption while maintaining the resolution needed for complex mixtures, maximizing efficiency in the lab. It also makes the wait time shorter. The general-purpose, silica-based, reversed-phase C18 Nova-Pak C18 Radial-Pak Column is based on the 4 µm particle technology and can be depended upon for nearly any system configuration, sample type, and instrument platform. Compared to a 5 µm column, Nova-Pak C18 Radial-Pak Column offers higher resolution, more efficient separations, and faster chromatography.
Using the Nova-Pak C18 Radial-Pak Column, you will find that there is more interaction time between the elutes and the bonded phase, making it possible for the sample to elute more slowly and allow more separation. This is because of the larger surface area offered by the lab equipment for the mobile phase to travel across.
The 4µ particle technology, on which the Nova-Pak C18 Radial-Pak Column is based, makes it possible for the lab equipment to provide an unparalleled range of possibilities for separation and high efficiency and carbon surface area. In addition to this, it enables you to leverage faster separations to produce more concentrated fractions, which, combined with less solvent consumption, significantly reduces laboratory operating costs. The bonded phases offered by the Nova-Pak C18 Radial-Pak Column facilitate high resolution and fast, efficient analysis. The smaller particles used in the column reduce solvent consumption without compromising the ability to resolve complex mixtures.
In addition to this, the Nova-Pak C18 Radial-Pak Column comes equipped with Waters proprietary end caps for optimal security and ease of use. Like all Waters lab equipment, the strictest quality control processes are used in the manufacturing of the Nova-Pak C18 Radial-Pak Column. Every step is carefully monitored throughout to ensure a high level of batch-to-batch reproducibility and to deliver the optimum quality that is the hallmark of Waters. Learn more about our manufacturing processes and the complete range of lab equipment that we carry through our website.
We recommend that you also invest in the system benchmarking Reversed-Phase QC Reference Material.
What pH Range Is Recommended For The Nova-Pak C18 Radial-Pak Column?
The Nova-Pak C18 Radial-Pak Column listed here offers an operating pH Range of 2-8.