Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
7 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Prep Column |
Surface Area |
335 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
19 mm |
Length |
300 mm |
Carbon Load |
19 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Preparative Columns |
Units per Package |
1 pk |
Symmetry C18 Prep Column, 100Å, 7 µm, 19 mm X 300 mm, 1/pk
With the Symmetry C18 Prep Columns, achieving exceptional repeatability year after year is significantly easier than with other comparable columns on the market. With each batch of new columns, it eliminates the need to revalidate and redevelop techniques. This allows you to avoid the labor expenditures associated with standard analytical columns that necessitate QC column testing.
With the monofunctionally bound C18 ligand included in these columns, you can maximize your analytical efficiency and precision in your lab. For maximum repeatability, the lab equipment also incorporates a high purity base-deactivated silica. Because the Symmetry C18 Prep Columns feature the industry's tightest ligand surface coverage (ligand density) standards, they generate fewer resolution changes and more consistent batch-to-batch results.
The lab equipment listed here is not the only product in the Symmetry Column series. It is available in a variety of particle sizes, chemistries, and dimensions. You can explore the extensive range by using our website and also shop for lab equipment directly from us.
The Symmetry C18 Prep Column, like all Waters equipment, is made in our cGMP, ISO9001, and ISO13485 certified facilities, where every step is monitored and the strictest conditions are assured. As a result, the lab equipment may give the most stringent standards on the market, ensuring reliable results every time. This is accomplished by designing Symmetry C18 Prep Columns with high purity raw materials and column packing techniques that provide the most repeatable HPLC column.
The Symmetry C18 Column allows you to increase lab efficiency and precision. The Symmetry C18 Column's monofunctional bound C18 ligand, along with high purity base-deactivated silica, allows the lab equipment to deliver unrivaled reproducibility. The Symmetry C18 Column also boasts the industry's tightest ligand surface coverage (ligand density) standards, resulting in minimum resolution changes and more consistent batch-to-batch results. As a result, the Symmetry C18 Column provides exceptional reproducibility year after year.
Protect the Symmetry C18 Prep Column by using the Symmetry Silica C18 Prep Guard Cartridge, 100Å, 7 µm, 19 mm X 10 mm, 1/pk. The cartridge is designed to prevent any chemical or physical contaminants from harming the analysis by filtering them out.
Is There A pH Limitation For The Symmetry C18 Prep Column?
The Symmetry C18 Prep Column listed here offers a minimum of 2 and a maximum of 8 pH.
What Are The Temperature Limits Of The Symmetry C18 Prep Column?
The maximum temperature is 45 C.