SKU: WAT066204
Symmetry C8 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk

Symmetry C8 Column | WAT066204


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    3.5 µm

  • Endfitting Type

    Waters

  • Pore Size

    100 Å

  • Format

    Column

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L7

  • Inner Diameter

    4.6 mm

  • Length

    100 mm

  • Carbon Load

    12 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Symmetry C8 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk

When it comes to HPLC separations, the reproducibility of columns is one of the most crucial choices a chromatographer can make. When creating Symmetry C8 Columns, reproducibility is the number one priority at Waters, starting with a commitment to maintaining the tightest specifications in the HPLC column industry. This starts with high purity raw materials, tightly controlled manufacturing processes, and column packing procedures that provide these superior, most reproducible HPLC results available.

Symmetry C8 Columns are able to supply these superior results by using the narrowest surface coverage specifications in the industry. Surface coverage, also known as ligand density, is one of the most parameters affecting reproducibility. With this in mind, the surface coverage requirements in Symmetry C8 Columns are the tightest on the market. This means you will experience minimal shifts in resolution and more reproducible results between columns and batches as a result of this innovative lab equipment.

In addition to these benefits, Symmetry C8 Columns deliver consistent performance by optimizing the two key factors that control column lifetime- hydrolytic stability of the packing material and mechanical stability of the packed bed. When columns last longer, laboratories can save money over time. Symmetry columns can last over 10,000 injections with minimal loss in efficiency, minimal increase in backpressure, and minimal change in retention time. Lifetime can be extended even further with the use of a Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk to reduce contamination.

This column’s chemistry features a monofunctionally bonded C8 ligand on a high purity base-deactivated silica, offering less retention for those looking for speed in their separations.

How Should I Prepare Samples For Use With Symmetry C8 Columns?

Sample impurities can often contribute to contamination in columns. In order to avoid this, using a column of the same chemistry before sample analysis can be beneficial. Oasis SPE extraction cartridges or Sep-Pak cartridges will both be good options. It is best to prepare the sample in the operating mobile phase or a mobile phase that is weaker than the mobile phase in order to achieve the best peak shape and sensitivity. If the sample is not dissolved in the mobile phase, ensure that the sample, solvent, and mobile phase are miscible in order to avoid sample and/or buffer precipitation.