Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
3.5 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
Column |
Surface Area |
335 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
4.6 mm |
Length |
75 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Symmetry |
Product Type |
Columns |
Units per Package |
1 pk |
Symmetry C8 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk
Symmetry C8 columns contain monofunctionally bound C8 ligands on a high-purity base-deactivated silica. Symmetry columns feature the tightest column specifications in the industry, resulting in highly reproducible chromatographic results.
Symmetry columns continue to establish and maintain the standard for HPLC drug testing, offering you confidence in your HPLC methods' long-term compliance. Symmetry Columns raise the bar in terms of HPLC Column performance. The high-purity silica packed in these Analytical columns ensures optimum performance through stringently controlled manufacturing methods. Symmetry Columns have unrivaled column-to-column and batch-to-batch reproducibility. Using the Symmetry C8 Column, you will be able to obtain optimum repeatability and superior peak form in your experiment.
The Symmetry C8 Column is manufactured in specifically authorized and state-of-the-art Waters facilities that are cGMP, ISO9001, and ISO13485 certified, ensuring the strictest conditions and thorough control over each stage of the manufacturing process. This allows us to manufacture Symmetry C8 Columns in accordance with the most stringent industry standards, ensuring consistent results every time. The Symmetry C8 Column produces consistent batch-to-batch results with minimum variance in resolution. With the Symmetry C8 Column, you gain excellent repeatability in your lab year after year.
Our website sells a variety of goods that are compatible with the Symmetry C8 Column, such as guards, vials, and elution plates. The website allows you to instantly shop for lab equipment as well as contact us with any questions. You can express your questions and concerns to a member of our staff in one of our many offices across the world.
You might also be interested in Symmetry C8 VanGuard Cartridge, 100Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk; Symmetry C8 VanGuard Cartridges are used to enhance the lifetime and performance of analytical columns by eliminating particle pollution from the mobile phase stream. This cartridge is designed to protect all Symmetry C8 analytical columns with 3.9 mm and 4.6 mm I.D. and 3.5 µm sorbent particles.
Why Does My L.C. System Keep Shutting Down Repeatedly?
HPLC pumps and systems have an overpressure setting to ensure system safety and to protect the columns and equipment. If your system is set too low or has too much backpressure, the pump may stop down to protect the L.C. system. Other causes could be that the lines need to be cleaned or that residual or crystallized material is blocking/choking the system.