SKU: WAT054475
Styragel HT 2, 500Å, 10 µm, 7.8 mm X 300 mm in THF, 100 - 10K, 1/pk

Styragel HT | WAT054475


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

You can use Styragel HT (High Temperature) Columns with aggressive solvents at high temperatures without sacrificing resolution or column lifetime. Packed with rigid 10 μm particles, a typical plate count exceeds 10,000 plates per column. These columns are extremely durable because of a narrow, particle-size distribution that results in a stable column bed. Suitable for both ambient and high-temperature analysis, the Styragel HT Columns offer excellent resolution of polymers in the mid-to-high molecular weight range.

Specifications

  • Chemistry

    GPC

  • Separation Mode

    SEC/GPC

  • Particle Substrate

    Polymer

  • pH Range Min

    2 pH

  • pH Range Max

    12 pH

  • Molecular Weight Range Min

    100

  • Molecular Weight Range Max

    10000

  • Particle Shape

    Spherical

  • Particle Size

    10 µm

  • Endfitting Type

    Waters

  • Pore Size

    500 Å

  • Format

    Column

  • Packing Solvent

    THF

  • System

    HPLC

  • Technique

    GPC

  • Inner Diameter

    7.8 mm

  • Length

    300 mm

  • UNSPSC

    41115709

  • Application

    Gel Permeation

  • Brand

    Styragel

  • Product Type

    Columns

  • Units per Package

    1 pk

Hazaradous Material This product contains hazardous material which requires special freight handling. Additional charges may apply.

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Styragel HT 2, 500 Å, 10 µm, 7.8 mm X 300 mm in THF, 100 - 10K, 1/pk

Styragel HT (High Temperature) Columns can withstand harsh solvents and high temperatures while maintaining resolution and column lifetime. They feature a plate count of more than 10,000 plates per column and are packed with 10m particles. Due to a narrow particle size distribution that results in a very stable column bed, these columns are extremely robust. The Styragel HT Columns are suitable for both ambient and high-temperature analysis and provide outstanding resolution of polymers in the mid-to-high molecular weight range.

At high temperatures, Styragel HT (High Temperature) Columns can be used with harsh solvents without losing resolution or column longevity. A typical plate count per column reaches 10,000 plates packed with hard 10 µm particles. Because of the tight particle size distribution that results in a stable column bed, these columns are exceptionally durable. The Styragel HT Columns are suitable for both ambient and high-temperature analysis and provide outstanding resolution of polymers in the mid-to-high molecular weight range.

The Styragel HT 2 analytical column is manufactured in the dedicated Waters chromatography chemistry manufacturing plant under the strictest cGMP, ISO 9002 conditions. Every lab equipment that gets manufactured in these state-of-the-art facilities goes through stringent testing and QA to ensure that you get the highest quality lab equipment that delivers consistent and reliable analysis results. You get the most critical performance features when you purchase the Styragel HT 2, including column efficiency, peak symmetry, column lifetime, and column-to-column reproducibility.

With the right lab equipment, you can boost your productivity. Our website has a variety of goods that are compatible with the Styragel HT 2 Column, such as guards, vials, and elution plates. You can shop for lab equipment directly from our website, as well as contact us with any questions.

You might also be interested in Polystyrene ReadyCal Standards 4 mL Kit. Thirty autosampler vials contain 4 polystyrene standards per vial. There are three separate molecular weight ranges in each kit, with 10 units of each of the three molecular weight standards. Just add solvent to the vial, let it stand for 2 hours, shake gently, and load into your autosampler for analysis. Each kit comes with detailed instructions for proper usage.

Why Is It Critical To Achieve High Resolution In Chromatography?

Resolution can be used to optimize separations because it is a function of peak width and retention time, both of which are inherent properties of the chromatographic process. The greater the level, the better the results can be examined and the more accurate they can be.