Separation Mode |
Reversed Phase |
Maximum Pressure |
6000 psi (415 Bar) |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Pore Size |
60 Å |
Format |
Sentry Guard Cartridge |
System |
HPLC |
USP Classification |
L20 |
Inner Diameter |
3.9 mm |
Length |
20 mm |
UNSPSC |
41115709 |
Application |
Carbohydrate |
Product Type |
Guards |
Units per Package |
2 pk |
Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm x 20 mm, 2/pk
The Waters Carbohydrate Sentry Guard Cartridge is an important piece of lab equipment that is used to extend and prolong the lifetime of the Carbohydrate Cartridge Column. This Carbohydrate Sentry Guard Cartridge works in conjunction with the analytical column and improves its performance by removing chemical and particulate contamination from the mobile phase stream.
The Waters Carbohydrate Sentry Guard Cartridge is specially designed to be compatible with the Carbohydrate Cartridge Column for reversed-phase Liquid Chromatography. As it is made using identical packing materials as the analytical column, the lab equipment is able to deliver the same level of performance as the analytical column. The Guard Cartridge is a single unit that can be attached directly to the inlet side of a Carbohydrate Cartridge Column.
By opting for the Carbohydrate Sentry Guard Cartridge, you will ensure that your UPLC analytical columns last longer without compromising their chromatographic analytical performance. The Guard Cartridge achieves this by removing unwanted pollutants from the columns and maintaining their UPLC, UHPLC, and HPLC separation efficiency.
Like all equipment manufactured by Waters, that Waters manufactures, the Carbohydrate Sentry Guard Cartridge is also manufactured under the strictest cGMP, ISO 9001 conditions. In addition to this, each unit is tested and certified for its use, guaranteeing that it will deliver optimal performance and enhance the selectivity, sensitivity, and speed of your analysis. Every step of the manufacturing process is strictly controlled and monitored to ensure that you receive only the best quality equipment for your lab.
The Carbohydrate Sentry Guard Cartridge has been designed for routine use and can tolerate pressures up to 6000 psi (415 Bar) in applications run on the ACQUITY UPLC System. The product listed here contains 60Å pore and 4 µm particles and is delivered in a packing of 2.
To find products to meet any analytical need, use the website to shop for lab equipment. You may also want to learn about the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
How Is The RF Value Calculated?
The Rf value of a compound is equal to the distance traveled by the compound divided by the distance traveled by the solvent front (both measured from the origin). For instance, if a particular compound travels 1.5 cm and the solvent front travels 6.0 cm, then the compound's Rf value is 0.25.