SKU: WAT046830
Nova-Pak C8 Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk

Nova-Pak C8 Sentry Guard Cartridge | WAT046830


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

Specifications

  • Chemistry

    C8

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Medium

  • Particle Shape

    Spherical

  • Particle Size

    4 µm

  • Pore Size

    60 Å

  • Format

    Sentry Guard Cartridge

  • Surface Area

    120

  • System

    HPLC

  • USP Classification

    L7

  • Inner Diameter

    3.9 mm

  • Length

    20 mm

  • Carbon Load

    4 %

  • UNSPSC

    41115709

  • Brand

    Nova-Pak

  • Product Type

    Guards

  • Units per Package

    2 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Nova-Pak C8 Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography. The Nova-Pak C8 Sentry Guard Cartridge is used in conjunction with the column so that it continues to deliver optimum performance throughout its lifetime.

Use the Nova-Pak C8 Sentry Guard Cartridge to protect your analytical HPLC column from damage by filtering out chemicals and particulates from the mobile stream. It is vital to note that the sorbents used in Waters Sentry Guard Cartridge are the same as the sorbents used in Waters HPLC columns and cartridges. As a result, it is critical to utilize lab equipment with the same sorbent as the column or cartridge you are using to get the best results.

When using the Nova-Pak C8 Sentry Guard Cartridge with high-performance/low-volume columns, you may notice some efficiency loss. When utilizing the lab equipment, Waters recommends that the same care should be taken when employing analytical columns. Only use miscible eluents to avoid precipitation inside the cartridge.

TheNova-Pak C8 Sentry Guard Cartridge, like all of our manufactured products, is prepared with ultra-pure chemicals under the most stringent conditions. In addition to this, our cGMP manufacturing facility's extensive QC procedures ensure batch-to-batch consistency.

Nova-Pak bonded phases' 4 µm compact particle size provides greater resolution, more efficient results, and faster chromatography by allowing scientists to use shorter columns, decreasing solvent usage, or longer columns to resolve even the most complicated mixtures.

In order to store your samples and analytes in a chemically stable, safe, leak-proof unit, invest in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The preslit PTFE/Silicone septa is ideal for numerous injections and sample storage because of its excellent resealing capabilities. It can operate at temperatures ranging from -40°C to 200°C. Waters' certified vials are the only ones on the market that have been tested using mass spectrometers and come with a certificate of analysis that includes the reference and vial scan for the manufacturing lot.

Is There A pH Limit For The Nova-Pak C8 Sentry Guard Cartridge?

The Nova-Pak C8 Sentry Guard Cartridge listed here is able to work well across the 2-8 pH range.