Chemistry |
GPC |
Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Molecular Weight Range Min |
500 |
Molecular Weight Range Max |
20000 |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
500 Å |
Format |
Column |
Packing Solvent |
THF |
System |
HPLC |
Inner Diameter |
4.6 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Brand |
Styragel |
Product Type |
Columns |
Units per Package |
1 pk |
Add the Styragel GPC Column to your lab equipment collection, as these narrow bore columns can cut your solvent consumption and disposal costs by as much as two-thirds.
Over the years, Waters has undertaken substantial research to improve GPC analysis by refining instrumentation, packaging materials, and technology. As a result, advances like the size-exclusion techniques employed in the Waters Styragel GPC Column have been developed, allowing you to expand beyond the original polymer analysis to encompass applications for separating small and big molecules from interfering matrices. Foods, pharmaceutical preparations, and natural goods are all included in them.
When high resolution is required, use the Styragel GPC column, which is a high-resolution GPC column with 5 µm particles and is suitable lab equipment for characterizing samples in the low- to mid-molecular range.
Waters provides you with the finest quality GPC products and skilled application support, so you can rely on the Styragel HR column for accurate and precise results. Because all of our facilities follow strict ISO, FDA, and cGMP criteria, the Styragel HR column is manufactured under the most stringent circumstances to ensure that you receive the finest quality chromatographic instrumentation and consumables.
We recommend that you also invest in the Styragel GPC Guard Column, 20 µm, 4.6 mm X 30 mm, 100 - 10K, 1/pk, in order to protect your analytical Styragel GPC column and ensure that it lasts a long time. The Guard Column, which is designed to function especially with the analytical column, is the ideal lab equipment for protecting it from contamination during the mobile phase. This implies the analytical column will not need to be replaced after a short period of time, and you will get consistent results for a long time.
Across What pH Range Does The Styragel GPC Column Operate?
The Styragel GPC Column listed here is able to operate well across the broad 2-12 pH range. However, this may be impacted by the temperature and pressures used, so it is important to adhere to the recommended temperature and pressure ranges as well.
How Do You Choose The Size For Exclusion Chromatography?
To achieve successful size exclusion chromatography, you must select a column with the appropriate pore size for the separation you want to achieve. Molecules that are too big to fit through any of the pores will be eluted first.