Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Endfitting Type |
Waters |
Pore Size |
60 Å |
Format |
Column |
Surface Area |
120 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
7 % |
UNSPSC |
41115709 |
Brand |
Nova-Pak |
Product Type |
Columns |
Units per Package |
1 pk |
Nova-Pak C18 Column, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pk
Get higher resolution and faster, more efficient chromatography with the Nova-Pak C18 Column. The shorter column offers less solvent consumption while maintaining the resolution needed for complex mixtures, maximizing efficiency in the lab. It also makes the wait time shorter. The Nova-Pak C18 Column is also suitable for nearly any system configuration, sample type, and instrument platform.
With the Nova-Pak C18 column, there is more interaction time between the elutes and the bonded phase, which makes it possible for the sample to elute more slowly and allow more separation. This is due to the larger surface area offered by the Nova-Pak C18 column for the mobile phase to travel across.
The Nova-Pak C18 column is a general-purpose, silica-based, reversed-phase column, based on innovative 4µ particle technology which makes it possible for it to provide an unparalleled range of possibilities for separation, as well as high efficiency and carbon surface area. In addition to this, you leverage faster separations to produce more concentrated fractions as well as using less solvent which significantly reduces laboratory operating costs. The bonded phases offered by the Nova-Pak C18 column facilitate high resolution and fast, efficient analysis. The smaller particles used in the column reduce solvent consumption without compromising the ability to resolve complex mixtures.
With the Nova-Pak C18 column, you can easily perform analysis across a pH range of 2-8. In addition to this, it comes end-capped with Waters proprietary end caps for optimal security and ease of use. Like all Waters lab equipment, the Nova-Pak C18 column is made under strict quality control processes that are monitored throughout to ensure a high level of batch-to-batch reproducibility and to deliver the optimum quality that is the hallmark of Waters.
You can shop for lab equipment, and check all related products and other variants of the same listing as well as our complete range of products to see our latest offerings in our catalog.
You may also be interested in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk, a chemically inert storage unit that can be used to securely place your samples, solvents, and solutions before or after analysis. Waters offers the only certified vials that are compatible with MS applications.
How Much Should The Band Spreading Be?
Band Spreading of a properly operating analytical system should be less than 100µL.