Chemistry |
GPC |
Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Molecular Weight Range Min |
0 |
Molecular Weight Range Max |
1000 |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
50 Å |
Format |
Column |
Packing Solvent |
THF |
System |
HPLC |
Inner Diameter |
7.8 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Brand |
Styragel |
Product Type |
Columns |
Units per Package |
1 pk |
Styragel Column, HR 0.5, 50Å, 5 µm, 7.8 mm X 300 mm, 0 - 1K, THF, 1/pk
Achieve high efficiency and unparalleled resolution in the low-to mid-molecular weight region with the Styragel HR Column. Packed with high-performance, fully porous, highly cross-linked styrene-divinylbenzene copolymer particles, the Styragel HR Column is the ideal lab equipment.
Rely on the Styragel HR Column for the high-resolution analysis of low-molecular-weight polymers, oligomers, and additives. The Styragel HR Column provides the high plate counts necessary for the analysis of these molecules as it is packed with 5 µm particles.
You can depend on the Styragel HR Column for providing reliable results, without the need to repeat analysis, saving time and analytical materials. This is because the facilities in which the Styragel HR Column is manufactured follow the strictest conditions and protocols for ISO, FDA, and cGMP guidelines. This results in the highest quality GPC instruments and products such as the Styragel HR Column.
Use the Styragel GPC Guard Column, 20 µm, 4.6 mm X 30 mm, 100 - 10K, 1/pk to protect your analytical Styragel HR column and ensure that it lasts a long time. The Guard Column protects the analytical column from any chemical or particulate contamination that may be present in the mobile phase as it is designed to work specifically with the analytical column. This means that you get reliable results for a long time without the need to replace the analytical column after a short duration.
Check all related products and other variants of the same listing as well as our complete range of products to see our latest offerings in our catalog. You can also find details regarding how to contact us as well as shop for lab equipment through the catalog.
How Is The Initial Efficiency Tests Performed On The Styragel HR Column?
Before you conduct the first analysis, make sure to test the system and the column. To do this, run a test sample using the recommended parameters for your system and column, making sure to record the results. The results collected will serve as a baseline to compare future performance. Along with the results, save the chromatograms from the tests conducted. For the column-efficiency test, record the retention times, system settings, and all experimental conditions so they may be reproduced as determined by the tests in the future as well and compared to analytical results.