Chemistry |
GPC |
Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Molecular Weight Range Min |
5000 |
Molecular Weight Range Max |
600000 |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
10000 Å |
Format |
Column |
Packing Solvent |
Toluene |
System |
HPLC |
Inner Diameter |
7.8 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Brand |
Styragel |
Product Type |
Columns |
Units per Package |
1 pk |
Styragel GPC Column, 5 µm, 7.8 mm X 300 mm, 5K - 600K, 1/pk
Styragel (High Resolution) HR Columns are high-resolution GPC columns packed with 5 m particles that are ideal for characterizing samples in the low- to mid-molecular range where high resolution is required. These Waters Styragel columns contain high-performance, fully porous, highly cross-linked styrene-divinylbenzene copolymer particles.
Waters is a market leader in Gel Permeation Chromatography (GPC) Analysis, providing a wide range of high-quality GPC products as well as expert application support as a result of extensive research and development in the field. Waters developed the Styragel HR HPC Column after extensive research, allowing you to conduct an in-depth polymer analysis that includes applications of small and large molecules.
The Styragel GPC HR Column can be used for high-resolution analysis of low-molecular-weight polymers, oligomers, and additives. This laboratory equipment is packed with 5-micrometer particles and has the high plate counts required for this type of analysis.
You can rely on your Styragel GPC HR Column to provide consistent, reliable results without the need to repeat analysis, saving you time and analytical materials. The Styragel GPC HR Column is produced at Waters facilities that adhere to the highest industry standards and conditions for ISO, FDA, and cGMP guidelines. As a result, we are able to provide you with the highest quality GPC instruments and products available in the industry.
If you would like to review additional Waters products that are compatible with the Styragel HR 5E Column, please review our brochure or browse through our website, where you can shop for lab equipmentto ensure all your laboratory needs are fulfilled. You can also connect with any member of our global support team to assist you with any queries, concerns, or guidance related to lab equipment.
You may also be interested in checking out the Styragel GPC Guard Column, 20 µm, 4.6 mm X 30 mm, 100 - 10K, 1/pk; these Styragel Guard columns protect and increase the column lifetime of your Styragel 7.8 mm or 4.6 mm ID columns. The Styragel GPC Guard Column is made from the same packing materials as the analytical column, and placing it in the system helps protect the column by removing chemical and physical contaminants from the mobile phase.
What Special Storage Considerations Must Be Followed For The Styragel HR Column?
If you plan to reuse the Styragel GPC HR Column again within 24 hours, you don't need to go through any special storage procedures. However, please make sure the column never dries out. For any longer intended storage periods, return the column to its box with the end plugs firmly in place for storage. Kindly ensure to never leave your Styragel GPC HR Column at elevated temperatures without consistent solvent flow. Otherwise, you run the risk of the column going dry and getting damaged.