Styragel HT (High Temperature) Columns can be used with aggressive solvents at high temperatures without sacrificing resolution or column lifetime. Packed with rigid 10 μm particles, a typical plate count exceeds 10,000 plates per column. These columns are extremely durable because of a narrow, particle-size distribution that results in a stable column bed. Suitable for both ambient and high-temperature analysis, the Styragel HT Columns offer excellent resolution of polymers in the mid-to-high molecular weight range.
Chemistry |
GPC |
Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Molecular Weight Range Min |
5000 |
Molecular Weight Range Max |
60000 |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
10000 Å |
Format |
Column |
Packing Solvent |
DMF |
System |
HPLC |
Technique |
GPC |
Inner Diameter |
7.8 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Application |
Gel Permeation |
Brand |
Styragel |
Product Type |
Columns |
Units per Package |
1 pk |
Styragel HT 4, 10000 Å, 7.8 X 300 mm Column in DMF, 5K - 600K
To be able to analyze polymers with mid-range molecular-weight distributions, purchase a Waters Styragel HT 4 Column. The most adaptable column for molecular weight analysis is this particular lab equipment. The packed-bed stability in Styragel HT 4 columns is improved by the use of 10 m particles with a narrow particle size distribution. In high-temperature GPC applications, these durable GPC columns provide remarkable column longevity. The lab equipment also performs consistently across a broad range of temperatures and solvents.
High-performance, highly cross-linked, and very porous styrene-divinylbenzene copolymer particles are crammed into the Styragel HT 4 Column. You can depend on the Styragel GPC column for precise results since Waters provides you with the highest quality GPC products and great application assistance. The Styragel HT 4 column is produced under the strictest conditions to guarantee that you obtain the highest quality chromatographic equipment and supplies because all of our facilities adhere to strict ISO, FDA, and cGMP regulations.
The Styragel HT 4 Column packing materials are made in a cGMP, ISO 9001-certified facility using ultra-pure reagents and were developed expressly for use with the ACQUITY UPLC System. To ensure good, repeatable performance, each batch of Styragel HT 4 Column packing material is chromatographically tested with acidic, basic, and neutral analytes, and the results are held to limited specification ranges. A Performance Chromatogram and Certificate of Batch Analysis are supplied on the eCordTM Intelligent Chip once each column has undergone an individual test.
You may also want to explore and invest in the Styragel GPC Guard Column, 20 µm, 4.6 mm X 30 mm in DMF, 100 - 10K, 1/pk. The guard column connects directly to the analytical column and prevents the entrance of any unwanted chemical or particulate matter into the mobile stream. This helps to extend the column’s lifetime as well as enhance its performance. It also ensures that you receive more accurate analysis results.
What Is The pH Range Offered By The Styragel HT 4?
The Waters Styragel HT 4 listed here is able to work well within the 2-12 pH range.
What Is The Molecular Weight Range Offered By The Styragel HT 4?
The Styragel HT 4 offers a minimum of 5,000 and a maximum of 60,000 molecular weight range.