Separation Mode |
SEC/GPC |
Particle Substrate |
Polymer |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Molecular Weight Range Min |
500000 |
Molecular Weight Range Max |
100000000 |
Particle Shape |
Spherical |
Particle Size |
15 - 20 µm |
Endfitting Type |
Waters |
Pore Size |
10000000 Å |
Format |
Column |
Packing Solvent |
THF |
System |
HPLC |
Technique |
GPC |
Inner Diameter |
7.8 mm |
Length |
300 mm |
UNSPSC |
41115709 |
Brand |
Styragel |
Product Type |
Columns |
Units per Package |
1 pk |
Styragel HMW 7, 10,000,000 Å, 15 - 20 µm, 7.8 mm X 300 mm in THF, 500K - 100M, 1/pk
Styragel HMW columns are perfect for use in high-molecular-weight applications since they are packed with a 20 m particle and make use of a unique 10 m frit to reduce polymer shearing. The Styragel HMW Columns were developed specifically to examine ultra-high molecular weight polymers that are susceptible to shearing. These innovative columns can be employed at either ambient or elevated temperatures and offer remarkable column durability.
The analytical column is created at specialized, cutting-edge facilities that Waters owns and manages. All water manufacturing facilities and plants adhere to the strictest ISO, FDA, and cGMP standards. Because every step of the manufacturing process was thoroughly inspected and managed, the lab equipment is of the greatest standard possible. You can rely on the Waters Styragel HMW 7 Columns to reliably deliver high quality and the desired results for liquid chromatography. The most crucial performance traits, such as column efficiency, peak symmetry, column longevity, and column-to-column repeatability, are provided by the Styragel HMW 7 Column.
For additional information about Waters products that are compatible with the Styragel Column, please refer to our brochure or visit our website. Use the Waters catalog and website to read up on our most recent and prospective technological advancements. To make sure that all of your laboratory needs are met, you can shop for lab equipment there. You can also contact any member of our global support staff for assistance or guidance if you have any issues with lab equipment.
We may also recommend you check out Polystyrene ReadyCal Standards 4 mL Kit; For autosamplers, there are thirty vials with four polystyrene standards in each. Each of the three molecular weight standards in each of the three molecular weight ranges is contained in ten units per package. To put the vial into your autosampler for analysis, just fill it with solvent, let it stand for two hours, give it a small shake, and load it. Complete usage instructions are included with each kit.
What Particular Storage Requirements Are Applicable to the Styragel Columns?
If you plan to use the Styragel Columns once more within 24 hours, no further storage precautions are required; however, you should keep an eye out for the column drying up. In order to store the column for longer lengths of time, replace the end plugs and place them in its box. If you maintain your Styragel Column at high temperatures without constant solvent flow, it will dry out and suffer damage.