Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Endfitting Type |
Waters |
Pore Size |
60 Å |
Format |
Column |
Surface Area |
120 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3.9 mm |
Length |
150 mm |
Carbon Load |
4 % |
UNSPSC |
41115709 |
Brand |
Nova-Pak |
Product Type |
Columns |
Units per Package |
1 pk |
Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk
Achieve less solvent consumption while maintaining the resolution needed for complex mixtures, maximizing efficiency in the lab using the Nova-Pak C8 Column. Other than delivering shorter wait times, the Nova-Pak C8 Column is also suitable for nearly any system configuration, sample type, and instrument platform. Based on the 4 µm particle technology, the Nova-Pak C8 Column is a general-purpose, silica-based, reversed-phase C8 column. When compared to a 5 µm column, the Nova-Pak C8 Column helps you achieve higher resolution, more efficient separations, and faster chromatography.
The Nova-Pak C8 Column offers a larger surface area for the mobile phase to travel, increasing the interaction time between the elutes and the bonded phase. This makes it possible for the sample to elute more slowly and allow more separation.
The innovative 4µ particle technology is a pivotal part of the general-purpose, silica-based, reversed-phase Nova-Pak C8 Column. This makes it possible for the lab equipment to provide an unparalleled range of possibilities for separation, as well as high efficiency and carbon surface area. The column also enables you to leverage faster separations to produce more concentrated fractions as well as using less solvent, which results in significantly reduced laboratory operating costs.
Using the bonded phases offered by the Nova-Pak C8 Column, it is easier to obtain high resolution and fast, efficient analysis. The smaller particles used in the column reduce solvent consumption without compromising the ability to resolve complex mixtures.
Perform analysis across a pH range of 2-8 easily using the Nova-Pak C8 Column. The column also comes equipped with Waters proprietary end caps for optimal security and ease of use. Like all Waters lab equipment, the Nova-Pak C8 Column undergoes strict quality control processes that are monitored throughout to ensure a high level of batch-to-batch reproducibility and to deliver the optimum quality that is the hallmark of Waters.
You can shop for lab equipment and check the complete range of Nova-Pak equipment that we offer, both from our website and catalog. The website will also enable you to find related products that work well together.
You may also want to explore the Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 100/pk.
What Is The Recommended Pressure For The Nova-Pak C8 Column?
The Nova-Pak C8 Column can tolerate pressures of up to 40 MPa (400 atm or 6000 psi). Exceeding this pressure limit can result in damaged equipment and unreliable results.