Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
4 µm |
Endfitting Type |
Waters |
Pore Size |
60 Å |
Format |
Column |
Surface Area |
120 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
7 % |
UNSPSC |
41115709 |
Brand |
Nova-Pak |
Product Type |
Columns |
Units per Package |
1 pk |
Nova-Pak C18 Column, 60Å, 4 µm, 2.1 mm X 150 mm, 1/pk
Utilize the Nova-Pak C18 Column for faster, more effective chromatography and improved resolution. In order to increase lab productivity, the shorter column uses less solvent while preserving the resolution required for complex combinations. Additionally, it reduces wait time. Almost any system configuration, sample type, and instrument platform can use the Nova-Pak C18 Column.
The Nova-Pak C18 column allows for more separation since there is more time for interaction between the elutes and the bonded phase. This allows the sample to elute more slowly. This is because the Nova-Pak C18 column offers a larger surface area for the mobile phase to travel across.
The Nova-Pak C18 column is a general-purpose, reversed-phase column made of silica. It is built on cutting-edge 4µ particle technology, which enables it to offer an unmatched range of separation possibilities, as well as high efficiency and carbon surface area. Additionally, you can use quicker separations to create fractions that are more concentrated while also using less solvent, which sharply lowers lab running expenses. The Nova-Pak C18 column's bonded phases provide excellent resolution and quick, effective analysis. The column's utilization of smaller particles lowers the amount of solvent needed to resolve complex combinations without sacrificing that ability.
You can browse our catalog for lab equipment and see our most recent offerings by looking at all connected items, different listing variations, and our whole product line.
You can conduct analysis with the Nova-Pak C18 column with ease over a respectable pH range. It also includes end caps made exclusively for Waters for maximum security and usability. The Nova-Pak C18 column, like all Waters lab equipment, is created using stringent quality control procedures that are continuously observed to ensure a high level of batch-to-batch reproducibility and to deliver the exceptional quality that is the company's trademark.
Invest in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk, and store your analytes in a chemically inert and safe vessel.
Across What pH Range Does The Nova-Pak C18 Column Operate?
The Nova-Pak C18 Column listed here is able to function well within the 2-8 pH.
What Is The Maximum Pressure That The Nova-Pak C18 Column Can Tolerate?
The maximum pressure that the Nova-Pak C18 Column can sustain is 6,000 psi (415 Bar).