Chemistry |
Phenyl |
|
Separation Mode |
Reversed Phase |
|
Particle Substrate |
Silica |
|
pH Range Min |
2 pH |
|
pH Range Max |
8 pH |
|
Temperature Limits |
45 C |
|
Maximum Pressure |
1500 psi (100 Bar) |
|
Endcapped |
Yes |
|
Silanol Activity |
Medium |
|
Particle Shape |
Spherical |
|
Particle Size |
4 µm |
|
Pore Size |
60 Å |
|
Format |
Radial-Pak Column |
|
Surface Area |
120 |
|
System |
HPLC Preparative |
|
Technique |
LC/MS, LC |
|
USP Classification |
L11 |
|
Inner Diameter |
8 mm |
|
Length |
100 mm |
|
Carbon Load |
5 % |
|
UNSPSC |
41115709 |
|
Brand |
Nova-Pak |
|
Product Type |
Columns |
|
Units per Package |
1 pk |
Nova-Pak Phenyl Radial-Pak Column, 60Å, 4 µm, 8 mm X 100 mm, 1/pk
The bonded phases of Nova-Pak Phenyl Radial-Pak Column, which come in particle sizes of 4 µm and 6 µm, provide great resolution in addition to quicker and more effective chromatography. You can use less solvent while preserving resolution for complicated mixes by employing the smaller particle size in combination with shorter column lengths. This specific listing is appropriate for the analysis of particles with a 4 µm and 60 pore size. However, 75, 150, and 300 mm steel columns of the Nova-Pak Phenyl Radial-Pak Column analytical columns with 4 µm particle size packing are readily accessible. To ensure that the lab equipment you purchase is exceptional quality, you can purchase it directly from our online store.
All Nova-Pak Phenyl Radial-Pak Columns are packaged using exact QC techniques, just like the rest of the lab equipment made by Waters, to guarantee batch-to-batch reproducibility. The packing materials are made in a cGMP, ISO 9001-certified facility using ultra-pure reagents and were created expressly for use with the ACQUITY UPLC System. Additionally, to ensure good, repeatable performance, each batch of Nova-Pak packing material is chromatographically tested with acidic, basic, and neutral analytes. The results are maintained within limited specification ranges. Every column is checked individually, and a Performance Chromatogram and Certificate of Batch Analysis are provided on the eCordTM Intelligent Chip to ensure that the product you receive from us will perform at its peak.
With reversed-phase applications, make use of the phenyl ligand in the Nova-Pak Phenyl Radial-Pak Column to achieve exceptional chemical selectivity. The 4 µm silica-based particle technology is the foundation of the Waters Nova-Pak Phenyl Radial-Pak Column series.
We recommend that you also explore and invest in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. The vial enables you to safely store your solvents, solutions, and samples in a secure and chemically inert environment to obtain the most accurate results. The only vials available for LC and LC/MS Analysis are those offered by Waters.
What Is The Nova-Pak Phenyl Radial-Pak Column's Available pH Range?
The Waters Nova-Pak Phenyl Radial-Pak Column listed here is able to function well within the 2-8 pH range.
What Is The Recommended Temperature Limit For The Nova-Pak Phenyl Radial-Pak Column?
For this particular Nova-Pak Phenyl Radial-Pak Column, Waters recommends a maximum of 45 C.