Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
Yes |
Bonding Technology |
ODS2 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
10 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4 mm |
Length |
250 mm |
Carbon Load |
12 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS2 Column, 80Å, 10 µm, 4 mm X 250 mm, 1/pk
With a predetermined carbon load of 11.5% and intermediate ligand density, the ODS2 packing utilized in the Spherisorb ODS2 Column makes the analytical column general-purpose, silica-based, reversed-phase C18 columns, which may be employed across a wide range of chromatographic demands.
You can get exceptional flexibility in improving processes and lowering solvent use by using the Spherisorb ODS2 Column. The chromatographic columns in the lab equipment are silica-based, all-purpose, robust, and very efficient. Shop for lab equipment on our website, and you can be sure that you are getting the greatest deal on genuine, original Waters lab equipment. When you choose to buy from us, you can also get in touch with a member of our team if you have any questions or concerns, either before or after the transaction.
The lab equipment is manufactured with column packing techniques that guarantee top performance each and every time. The Spherisorb ODS2 Column is designed to take into account the effects of all process variables, including slurry solvent selection, packing pressure duration, temperature, flow rate, and slurry volume. This yields the best peak symmetry, highest efficiency, and best column stability.
The Spherisorb ODS2 Column is produced in the dedicated Waters chromatography chemistry manufacturing plant under the strictest cGMP, ISO 9002 guidelines, much like all of the equipment offered by Waters that is made by us. For the most important performance characteristics—column efficiency, peak symmetry, column longevity, and column-to-column reproducibility—the column is produced with ultra-pure reagents. This enables you to use the Waters Spherisorb ODS2 Column to reliably fulfill the quality criteria necessary for liquid chromatography.
We recommend that you also invest in the Spherisorb ODS2 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pk. The guard cartridge is designed to prevent any chemical or particulate matter from entering the mobile phase and interfering with the analysis. This increases the lifetime of the column as well as ensures you receive more accurate results.
What Is The pH Range Offered By The Spherisorb ODS2 Column?
The Waters Spherisorb ODS2 Column listed here is able to work across the 2-8 pH range.
What Is The Maximum Pressure That The Spherisorb ODS2 Column Can Tolerate?
The Spherisorb ODS2 Column has been designed to withstand a maximum of 6,000 psi (415 Bar) pressure.