Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Bonding Technology |
ODS1 |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L1 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
6 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb ODS1 Column, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pk
The Spherisorb ODS1 Column is a durable, general-purpose, reversed-phase C18 column made of silica that has been meticulously engineered to handle a variety of applications. You can address all of your lab's liquid chromatography problems by incorporating the Spherisorb ODS1 Column into your system.
With a set carbon load of 6.2 percent, the packing employed in the production of the Spherisorb ODS1 Column has a low ligand density. Peak symmetry, column efficiency, column longevity, and column-to-column reproducibility are four significant performance features that can be addressed with this packing. Additionally, because Waters' column packing techniques are designed to assure maximum performance at all times, you may purchase lab equipment with confidence in its performance.
The Spherisorb ODS1 analytical column, like all Waters lab equipment, is made in a cGMP, ISO 9001 certified and dedicated Waters facility with ultra-pure reagents. Each Spherisorb ODS1 Column is tested independently, and a copy of the test chromatogram is included with each column to ensure you have confirmation of its quality.
With the right lab equipment, you can boost your productivity. You can shop for lab equipment that meets your needs on our website, as well as evaluate Waters' other items for potential purchases. Our website includes a comprehensive list of equipment, including an overview of all Spherisorb Column kinds, comparable offerings, and system-compatible equipment.
You may also be interested in reviewing Neutrals QC Reference Material; the Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. This kit contains one ampule with 10 μL/mL acetone, 0.25 mg/ mL naphthalene, and 0.4 mg/ mL acenaphthene in 50/50 acetonitrile/water, 2 mL.
What Is The pH Range That The Spherisorb ODS1 Reverse-Phase Column Can Effectively Manage?
The Spherisorb ODS1 Column Reverse Phase Column has a pH range of 2 to 8 and can endure up to 6000 psi of pressure (415 Bar). We do not recommend running outside of the stated operating range because it can affect the column's longevity, as well as other parameters like operating temperature and buffer type.