Chemistry |
Amino (NH2) |
Separation Mode |
Normal-Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
6000 psi (415 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Parker-style |
Pore Size |
80 Å |
Format |
Column |
Surface Area |
220 |
System |
HPLC |
USP Classification |
L8 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
2 % |
UNSPSC |
41115709 |
Brand |
Spherisorb |
Product Type |
Columns |
Units per Package |
1 pk |
Spherisorb Amino (NH2) Column, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pk
Get the best column stability and highest efficiency along with best peak symmetry by using the Spherisorb Amino (NH2) Column. Rely on the Spherisorb Amino (NH2) Column to address the effects of all process parameters such as slurry solvent choice, packing pressure time, temperature, flow rate, and slurry volume. This is because the Spherisorb Amino (NH2) Column is designed to understand the limitations of the processes and overcome them.
If you require outstanding flexibility in optimizing methods and reducing solvent consumption, the Spherisorb Amino (NH2) Column is the most suitable lab equipment to meet your needs. The silica-based column is designed to be general-purpose, durable, and high-efficiency chromatographic columns.
Consistently meet the quality standards required for liquid chromatography by adding the Waters Spherisorb Amino (NH2) Column to your lab tools. As with all other lab equipment made by Waters, the Spherisorb Amino (NH2) Column is manufactured in the dedicated Waters chromatography chemistry manufacturing plant under the strictest cGMP, ISO 9002 conditions. The analytical column is made using only the purest reagents and several tests are run at each step to ensure that you receive only the highest quality equipment.
By adding the Waters Spherisorb Amino (NH2) Column to your arsenal of lab tools, you will get the most critical performance features in one column: column efficiency, peak symmetry, column lifetime, and column-to-column reproducibility.
Learn more about our manufacturing processes and plants using our website. The website also contains information about the technologies used in our products and allows you to shop for lab equipment directly from us. This will make certain that you receive authentic and original Waters products.
Extend the lifetime of your analytical column by using the Spherisorb Amino (NH2) Guard Cartridge, 80Å, 5 µm, 4.6 mm X 30 mm, 3/pk in conjunction with the column. The guard cartridge performs this task by eliminating all particulate and chemical contaminants from the mobile phase. Thus, it is the ideal lab equipment as it extends the column’s lifetime and ensures that you always get consistent and reliable performance from the column.
What pH Range Can The Spherisorb Amino (NH2) Column Tolerate?
The Spherisorb Amino (NH2) Column works with an operating pH range of 2-8. It is important to note that the column lifetime will also depend on the operating temperature and the type of buffer used.